Navien Furnace: IAQ accessory outputs
IAQ accessory outputs on a Navien furnace: Accessory contacts follow blower and heating or fan operation.
Applies to: Systems with IAQ accessories
How to fix iaq accessory outputs: step by step
- Electronic air cleaner (EAC): 120 VAC output is on when the blower is energized and off when the blower stops.
- Humidifier (HUM): energized in Heating mode when the humidistat calls for humidity; removed when the blower stops.
- Dehumidifier (DEHUM): on when the dehumidifier is enabled and the blower runs in Fan mode; off when the blower stops.
- Check these outputs at the accessory terminals when troubleshooting IAQ equipment.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NPF installation and operation manual, p. 99. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.