Navien Furnace: Vent pipe connection to exhaust collar
Vent pipe connection to exhaust collar on a Navien furnace: Use the correct lubricant and method when connecting vent pipe to the collar. No primer or cement is used on the appliance connection.
Applies to: Exhaust collar connection, 2 in or 3 in vent
How to fix vent pipe connection to exhaust collar: step by step
- Cut the vent pipe square at 90 degrees and deburr it before fitting.
- Lubricate the pipe end with water only, never grease.
- Mark the pipe 2-3/4 in (70 mm) from the end.
- Push the pipe into the collar with a twisting motion until it bottoms out in the socket.
- Tighten the clamp with a 5/16 in (8 mm) socket to seal the joint.
- Do not use primer or cement on the appliance connection.
If the unit shows an error code, look it up: Navien Furnace codes
More commissioning tips for furnace
Source: Navien NPF installation and operation manual, p. 61. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.