Navien Furnace: Choosing the furnace location and airflow orientation
Choosing the furnace location and airflow orientation on a Navien furnace: Locate the furnace centrally to the air distribution system and keep return grilles and registers open. Ducts cannot attach to the back of the furnace. Upflow models can take return on a side or the bottom. Horizontal left and downflow models must take return at the bottom (end opposite the discharge).
Applies to: Upflow, downflow and horizontal left NPF700
How to fix choosing the furnace location and airflow orientation: step by step
- Place the furnace centrally to the existing or planned duct system.
- Make sure return grilles and warm air registers are not blocked or closed.
- Upflow: attach the return to either side or the bottom.
- Downflow and horizontal left: attach the return to the bottom only.
- Keep the vent/flue routing and combustion air intake short; piping length can limit the location.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NPF installation and operation manual, p. 25. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.