Navien Furnace: Purge gas supply line using MAX mode
Purge gas supply line using MAX mode on a Navien furnace: Runs the burner at full output with the gas line open so air is pushed out of the supply piping. Only steps 2 to 7 are on these pages; step 1 is not shown.
Applies to: NPF700 hydro-furnace gas line purging
How to fix purge gas supply line using max mode: step by step
- Press and hold the Menu and Back buttons together for 3 seconds, then select Special Operations.
- Press Up or Down to reach MAX, then press OK to select the mode.
- Press Back twice to return to normal operation.
- Run space heating so the gas in the supply line is purged.
- Leave the furnace on until it shuts down from lack of gas, then turn it off.
- Loosen the three knobs on the upper front cover counterclockwise and remove the cover.
If the unit shows an error code, look it up: Navien Furnace codes
More service & test modes tips for furnace
Source: Navien NPF installation and operation manual, p. 49. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.