Navien Furnace: Prepare vent pipe and fittings
Prepare vent pipe and fittings on a Navien furnace: Clean and prepare pipe so debris cannot block the exhaust, combustion air inlet or condensate drain.
Applies to: NDF600 series furnaces
How to fix prepare vent pipe and fittings: step by step
- Clean and deburr all pipe cuts, including uncut lengths.
- Remove all shavings from the pipe before assembly.
- Use the correct cleaner, primer and cement when the pipe is not PVC.
- For ABS intake, use all-purpose cleaner and ABS to PVC transition cement.
- For CPVC intake, use all-purpose cleaner, clear or purple primer and all-purpose cement approved for the purpose.
- Clean out the inducer collar after installation, since initial shavings can block the inducer collar drain.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NDF installation and operation manual, p. 25, 30, 31. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.