Updated · by Aurora Star Tech Inc.

Concentric vent kit selection on a Navien furnace: Approved concentric vent termination kits for this furnace series.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NDF600 series furnaces with concentric venting

How to fix concentric vent kit selection: step by step

  1. Use a 2 in IPEX vent kit #196005 or a 3 in IPEX vent kit #196006.
  2. If using 1-1/2 in vent material with a concentric kit, use an increase coupling to connect to the 2 in concentric kit.
  3. Follow the concentric termination manufacturer instructions for installation.
  4. Keep straight vertical runs offset so condensate runs against the vent walls.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Furnace codes

Source: Navien NDF installation and operation manual, p. 32. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.