Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Navien Furnace: Auto water fill connection

Updated · by Aurora Star Tech Inc.

Auto water fill connection on a Navien furnace: The furnace has a motorized auto-fill valve. If a water line is available, connect it so the furnace fills itself. The valve can be moved to the left side of the furnace using the conversion section (2.14).

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NPF700 series

How to fix auto water fill connection: step by step

  1. Remove the rubber cap and the two screws from the auto water fill connection (upflow/downflow and horizontal models differ slightly).
  2. Install the auto water fill adapter with the removed screws.
  3. Connect an NPT 1/4 in pipe to the adapter.
  4. Check the water level on the front control panel after filling and refill if needed.
  5. Keep the water inlet plug and cover closed, or the interlock will stop the unit.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Furnace codes

More commissioning tips for furnace

Source: Navien NPF installation and operation manual, p. 43. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.