Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Navien Error Code E615 03: Abnormal flame signal input (Furnace)

Updated · by Aurora Star Tech Inc.

Navien error code E615 03 on a furnace means: Abnormal flame signal input. It is also called Navien diagnostic code E615 03.

Critical severityFurnaceNPF

Homeowner? What Navien code E615 03 means for you

Stop and call Your furnace is reporting: Abnormal flame signal input. This code is a safety shutdown. Turn the furnace off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Navien error code E615 03 mean?

Fault in the flame signal input.

Applies to: NPF Condensing Hydro-furnace

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Navien Furnace codes

CodeMeaning
E517 00Abnormal DIP switch settings
E593 00Abnormal front panel keys
E594Abnormal EEPROM operation
E594 00Abnormal EEPROM operation
E615Controller fault (sub codes 01, 03, 04, 05)
E615 01Abnormal overheat controller feedback
E615 04Abnormal ADC reference voltage
E615 05Abnormal MCU
E740Abnormal outdoor temperature sensor (sub codes 01, 02)
E740 01, 02Abnormal outdoor temperature sensor operation
E762Vent pipe not detected by Vent Installation Detector (VID)
E762 00Improper vent pipe installation

All Navien Furnace error codes →

Navien code E615 03: homeowner questions

What does Navien code E615 03 mean?

Abnormal flame signal input. Fault in the flame signal input.

Is it safe to keep using my furnace with code E615 03?

No. Code E615 03 is a safety shutdown, so keep the furnace off until a licensed technician has checked it.

Can I reset Navien code E615 03 myself?

Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.

Who can fix Navien code E615 03 near me?

Aurora Star Tech Inc. repairs Navien furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Furnace Not Turning On: What to Check · Furnace Blinking Light: What the Flash Codes Mean

Troubleshooting guides

Source: NPF Condensing Hydro-furnace installation and operation manual, p. 128. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair