How Your Furnace, Boiler, Heat Pump & Water Heater Works
How your furnace, boiler, heat pump, mini-split, tankless water heater or fireplace works, in plain language: what happens in order when it starts, heats, cools or defrosts, what is normal to see and hear, and when to call a technician.
How Bosch Air Handler works
How Bosch Boiler works
- Combi comfort and economy modes Domestic hot water
- First power-up purge and trap filling Startup
- Frost protection setup Freeze protection
- Heating call, anti-cycle and pump post purge Heating
- Tank priority (ZBR with DHW tank) Domestic hot water
How Bosch Heat Pump works
- Crankcase heater and reversing valve behaviour Startup
- Demand defrost Defrost
- Operating limits and compressor protections Other
How Bosch Tankless Water Heater works
- Flow-activated hot water call Domestic hot water
How Carrier Furnace works
- Furnace blower with outdoor A/C: cooling and continuous fan Cooling
- Single-stage 80% furnace: heating cycle, blower delays and shutdown Heating
- Single-stage 80% furnace: ignition sequence and retries Ignition
How Carrier Heat Pump works
- Non-communicating heat pump: cooling with 5-minute compressor delay (HK32EA003/008) Cooling
- Non-communicating heat pump: heating cycle (HK32EA001/007 and 003/008) Heating
- Non-communicating heat pump: time/temperature defrost and Quiet Shift Defrost
- Single-stage communicating heat pump: demand defrost, Auto interval and Quiet Shift-2 Defrost
- Single-stage communicating heat pump: pressure switch protection and lockout Other
- Single-stage communicating heat pump: time delays and operating functions Startup
- Variable-speed heat pump: demand defrost with Auto interval Defrost
- Variable-speed unit: high pressure switch protection and lockout Other
- Variable-speed unit: low pressure protection and lockout Other
- Variable-speed unit: power-up and compressor time delays Startup
How Flameworks Gas Fireplace works
How FlowMax Boiler works
- DHW call with pump overrun and priority Domestic hot water
- Heating and DHW frost protection Freeze protection
- Heating call with restart delay and pump overrun Heating
- Switch-on and mode selection Startup
- Switched OFF at the control panel Standby/shutdown
How Glow Brand Boiler works
- Anti-frost pre-heat Freeze protection
- Anti-legionella cycle Other
- Central heat call and post purge Heating
- Ignition and retry Ignition
- Indirect tank call and priority Domestic hot water
- Power-up and de-air Startup
How Goodman Furnace works
- Cooling airflow ramping profiles A to D Cooling
- Dual fuel heat pump to gas furnace transition Heating
- Heating mode sequence of operation Heating
- Normal power-up sequence Startup
How Goodman-Amana-Daikin Air Conditioner works
How Goodman-Amana-Daikin Air Handler works
How Goodman-Amana-Daikin Furnace works
- Cooling and fan only Cooling
- Cooling and fan only Cooling
- Gas heat call, first and second stage Ignition
- Gas heat call and shutdown Ignition
- Low and second stage cooling with the furnace blower Cooling
- Two-stage gas heat call with ramped blower Heating
How Goodman-Amana-Daikin Heat Pump works
- Communicating defrost and forced defrost Defrost
- Communicating heat pump heat, balance point and auxiliary heat Heating
- Heat pump heat with electric backup stages Heating
- Timed defrost with sensor and override Defrost
How Gree Mini-Split works
- Anti-cold-air indoor fan delay Heating
- Automatic defrost Defrost
- Automatic defrost Defrost
- Compressor protections and lockouts Other
- Compressor restart delay and minimum run time Startup
- Cooling, dry and fan modes (outdoor logic) Cooling
- Cooling and dry mode (multi-zone) Cooling
- Cooling and dry mode with protections Cooling
- Cooling mode Cooling
- Dry (dehumidify) mode Cooling
- Heating, defrost, oil return and mode conflict Heating
- Heating mode Heating
- Heating mode (outdoor logic) and special modes Heating
- Heating mode and anti-cold-air Heating
- Indoor coil anti-freeze protection Freeze protection
How Heat & Glow Gas Fireplace works
- Direct spark ignition with lockout Ignition
How HTP Boiler works
- Central heat call Heating
- Ignition retries and lockout Ignition
- Indirect water heater call Domestic hot water
- Outdoor reset and warm weather shutoff Heating
- Standby and over-temperature protection Standby/shutdown
How ICP Heat Pump works
- Heat pump: cooling cycle Cooling
- Heat pump: defrost board interval and defrost timers Defrost
- Heat pump: heating cycle with supplemental heat Heating
How KeepRite Air Conditioner works
- Split A/C: cooling cycle with standard thermostat or communicating control Cooling
- Split A/C: pressure switch and thermal cutout protection and lockout Other
How KeepRite Furnace works
- Furnace blower with outdoor A/C: cooling, dehumidify and continuous fan Cooling
- Furnace used with a heat pump (dual fuel blower timing) Other
- Modulating 95% furnace: adaptive heating, staging and blower delays Heating
- Modulating 95% furnace: ignition sequence and retries Ignition
- Single- and two-stage 95% furnace: ignition sequence and retries Ignition
- Single-stage 95% furnace: heating cycle and blower delays Heating
- Two-stage 95% furnace: low/high heat, staging and blower delays Heating
How KeepRite Heat Pump works
- Heat pump (Fast #1174185 board): defrost interval, Quiet Shift and speed-up test Defrost
- Heat pump: cooling cycle Cooling
- Heat pump: heating cycle with supplemental heat Heating
- Heat pump: time/temperature defrost and Quiet Shift 2 Defrost
- Heat pump with 5-minute compressor delay: cooling and heating start Cooling
How Kinghome Heat Pump works
- Compressor, expansion valve and fan startup/stop rules Startup
- Defrost and oil return Defrost
- Pressure, discharge temperature and fan protections Other
How Kinghome Mini-Split works
How Lennox Furnace works
- Continuous fan with heat or cool calls Standby/shutdown
- Cooling call on single-stage furnace blower Cooling
- Single-stage furnace gas heating cycle Heating
- Single-stage furnace ignition retries and watchguard Ignition
- Two-stage furnace heating with single-stage thermostat Heating
- Two-stage furnace ignition retries and watchguard Ignition
- Two-stage variable speed cooling call Cooling
- Two-stage variable speed furnace heating with two-stage thermostat Heating
How Lennox Heat Pump works
- Demand defrost cycle Defrost
- Heat pump cooling call Cooling
- Heat pump first-stage heating Heating
How Majestic Gas Fireplace works
- Millivolt: call for heat Heating
- Millivolt: lighting the pilot Ignition
- Millivolt: satisfied and shutdown Standby/shutdown
- Optional thermostat blower (BLOTBLDV) Other
- Signature Command: flame height control Heating
- Signature Command: pilot and main burner ignition Ignition
- Signature Command: pilot flame loss and lockout Other
- Signature Command: power up Startup
- Signature Command: shutdown Standby/shutdown
How Maxitrol Gas Fireplace works
- GV60 remote-controlled valve startup Ignition
How Midea Furnace works
- Failed ignition and re-ignition Ignition
- High fire heat call (W1 + W2) Heating
- Low fire heat call (W1 only) Ignition
- Refrigerant leak sensor response (A2L coil) Other
How Midea Heat Pump works
How Midea Mini-Split works
- Defrost mode Defrost
- Start protection and compressor stop rules Startup
How Mitsubishi Mini-Split works
- Drain overflow protection (P5) Pump/purge
- Freezing and overheating protection (P6) Freeze protection
How Napoleon Gas Fireplace works
- Manual pilot lighting and shutdown Ignition
How Noritz Tankless Water Heater works
- Auto Learning recirculation Pump/purge
- Freeze prevention heaters and pump Freeze protection
- On-demand heating cycle Domestic hot water
- Other recirculation modes Pump/purge
How NTI Boiler works
- Central heat call (CH1) from call to satisfied Heating
- Demand satisfied and shutdown Standby/shutdown
- Failed ignition and lockout Ignition
- Freeze protection stages Freeze protection
- Indirect tank (DHW) call Domestic hot water
- Light-off sequence and retries Ignition
- Normal shutdown Standby/shutdown
- Power-on and mode sequence Startup
- Power-up and what lets the boiler start a call Startup
- Safety stops, holds and lockouts Other
How Proflame Gas Fireplace works
How Rheem Furnace works
- Gas heat call, direct spark ignition and retry Ignition
- Gas heat call, hot surface ignition and retry Ignition
- Gas heat call, ignition and retry (direct spark) Ignition
- Heating call sequence of operation (Honeywell integrated control, direct spark ignition) Heating
- Heating ignition and blower sequence Ignition
- Retry sequence when burners do not light or flame is not sensed Ignition
- Two-stage gas heat call, ignition on high fire and retry Ignition
- Two-stage heat call, high-fire light-off and staging Ignition
- Two-stage heating cycle and staging Heating
How Rheem Heat Pump works
How Rinnai Air Handler works
- Circulating pump exercise Pump/purge
- Continuous fan Other
- Cooling call, single-stage thermostat Cooling
- Heating call, single-stage thermostat Heating
How Rinnai Boiler works
- DHW run limit and heating restart Domestic hot water
How Rinnai Furnace works
- Ignition failure and flame loss retry Ignition
- Normal shutdown and cool-down Standby/shutdown
- Normal start and heating Startup
How Rinnai Tankless Water Heater works
- Built-in freeze protection and power loss Freeze protection
- Smart-Circ recirculation Pump/purge
How Skymark Air Conditioner works
- Cooling cycle Cooling
- Gas heating cycle Heating
How Trane Air Handler works
- Modular blower cooling call (single and two-stage) Cooling
- Modular blower heat pump heating call (single and two-stage) Heating
How Trane Furnace works
- Cooling and heat pump calls on S8 furnace control Cooling
- Cooling fan-off delay Cooling
- First-stage gas heating Heating
- Heating call sequence of operation Heating
- Heating sequence of operation Heating
- Second-stage gas heating (S8X2 only) Heating
How Trane Heat Pump works
- Heat pump demand defrost Defrost
How Viessmann Boiler works
- Storage tank (cylinder) heating Domestic hot water
How York Furnace works
- Furnace heating cycle Heating
- Furnace ignition retry and lockout Ignition
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.