Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

KeepRite furnace: Modulating 95% furnace: adaptive heating, staging and blower delays

Updated · by Aurora Star Tech Inc.

A KeepRite 9MAE modulating furnace is designed to learn your house. Rather than blasting at one level, it adjusts its flame to match the heat your home needs. This page describes how it chooses that level and how the blower follows.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the KeepRite furnace works: Modulating 95% furnace: adaptive heating, staging and blower delays

What this is. A KeepRite 9MAE modulating furnace is designed to learn your house. Rather than blasting at one level, it adjusts its flame to match the heat your home needs. This page describes how it chooses that level and how the blower follows.

What happens, in order. The furnace starts in intermediate or maximum heat. After 45 seconds at intermediate, it moves to minimum heat or to a rate it calculates from earlier heating runs. The very first cycle after power returns runs at minimum heat, since the furnace has nothing to learn from yet. Later, if the calculated rate is between 40 and 99 percent, it runs 45 seconds of intermediate, then that rate for up to 19 minutes, then maximum if heat is still wanted. A calculated 100 percent simply means maximum only. After a power outage, the stored rate is forgotten: 45 seconds intermediate, 19 minutes minimum, then maximum. A two-stage thermostat can force maximum heat at any time. The blower starts 45 seconds after the gas opens on intermediate, or 25 seconds on maximum. When heat is satisfied, the gas closes, the inducer runs 15 seconds more, and the blower runs on at a gentle minimum-heat airflow for a set delay, typically 2 minutes. With a compatible communicating control, the furnace can modulate over its full range.

What is normal. Long, quiet cycles, airflow that changes speed, and a longer first cycle after any power cut.

Safe checks. Keep filters clean and vents open, and confirm the thermostat is on Heat.

When to call. If the house stays cold, the furnace runs only at one level or a fault light appears, book Aurora Star Tech.

Key times at a glance

WhatHow long or how much
Intermediate heat start time45 s
Adaptive rate run timeup to 19 min
Blower-on delay, intermediate45 s
Blower-on delay, maximum25 s
Airflow change delay5 s
Inducer post-purge15 s
Blower-off delay options90 / 120 / 150 / 180 s
Blower-off delay factory120 s

Applies to: ICP (F-G)9MAE modulating 95% furnace

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the KeepRite furnace

What is the Modulating 95% furnace: adaptive heating, staging and blower delays on a KeepRite furnace?

A KeepRite 9MAE modulating furnace is designed to learn your house. Rather than blasting at one level, it adjusts its flame to match the heat your home needs. This page describes how it chooses that level and how the blower follows.

Is it normal for my KeepRite furnace to do this?

Long, quiet cycles, airflow that changes speed, and a longer first cycle after any power cut.

Who can service my KeepRite furnace near me?

Aurora Star Tech Inc. repairs and services KeepRite furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977