Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Goodman-Amana-Daikin furnace: Low and second stage cooling with the furnace blower

Updated · by Aurora Star Tech Inc.

If you have a two-stage Goodman, Amana or Daikin furnace with a digital display, its blower also moves air for your central air conditioner. This page explains what happens inside the furnace when you ask for cooling.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the Goodman-Amana-Daikin furnace works: Low and second stage cooling with the furnace blower

What this is. If you have a two-stage Goodman, Amana or Daikin furnace with a digital display, its blower also moves air for your central air conditioner. This page explains what happens inside the furnace when you ask for cooling.

What happens, in order. The thermostat asks for low or second stage cooling, and the display shows 1AC or 2AC. The outdoor compressor and condenser fan start. After a short cool-on delay, the furnace blower starts at its cooling speed, and if you have an electronic air cleaner it is switched on with it. When the room is cool enough and the thermostat is satisfied, the compressor stops and a cool fan off-delay begins, which lets the blower keep moving air so the last bit of cooling is not wasted. When that delay finishes, the blower and the air cleaner switch off.

What is normal. The low stage runs for long, quiet stretches and is the main way the house stays cool. The second stage only joins in on hotter days. Expect the blower to continue briefly after the outdoor unit stops, and the display to show 1AC or 2AC while cooling.

Safe checks. Make sure the thermostat is on Cool and set below room temperature, the filter is clean, the supply and return vents are open, and the outdoor unit is free of leaves, grass clippings and cottonwood fluff. Check the breaker.

When to call a technician. Warm air from the vents while the outdoor unit runs, an outdoor unit that never starts, ice on the indoor line, or water leaking. Aurora Star Tech can service your furnace and air conditioner together.

Applies to: Goodman GC9C96 / GM9C96 / AC9C96 / AM9C96; Daikin DR96TN / DD96TN; Goodman GM9S96 family

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the Goodman-Amana-Daikin furnace

What is the Low and second stage cooling with the furnace blower on a Goodman-Amana-Daikin furnace?

If you have a two-stage Goodman, Amana or Daikin furnace with a digital display, its blower also moves air for your central air conditioner. This page explains what happens inside the furnace when you ask for cooling.

Is it normal for my Goodman-Amana-Daikin furnace to do this?

The low stage runs for long, quiet stretches and is the main way the house stays cool. The second stage only joins in on hotter days. Expect the blower to continue briefly after the outdoor unit stops, and the display to show 1AC or 2AC while cooling.

Who can service my Goodman-Amana-Daikin furnace near me?

Aurora Star Tech Inc. repairs and services Goodman-Amana-Daikin furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977