NTI boiler: Demand satisfied and shutdown
This page covers what an NTI Trinity Tft boiler does at the end of a heating or hot water call, once the thermostat or tank has what it wanted.
How the NTI boiler works: Demand satisfied and shutdown
What this is. This page covers what an NTI Trinity Tft boiler does at the end of a heating or hot water call, once the thermostat or tank has what it wanted.
What happens, in order. The call ends when the thermostat or tank aquastat opens, or when the water temperature reaches the target plus a small margin. The gas valve then closes and the flame goes out. The combustion fan keeps running for a short post-purge to push remaining gases out through the vent. After that, the fan should settle and be idle. A fan blowing hard with no flame is not normal and can point to a loose signal cable or missing power to the control.
What is normal. A fan that keeps running for a short while after the flame goes out, pumps that continue briefly or stop when demand ends, and a quiet boiler between calls. The display returns to its summary page, ready for the next request.
Before service. Technicians wait for the post-purge to finish, then shut off the gas and power. That order matters, which is one more reason not to open the boiler yourself.
Safe checks. If you notice the fan roaring when no one is asking for heat, note the time and any code, check the thermostat is not fighting you, and switch the boiler off at the front switch if it is not settling. A hold or lockout 67 is the boiler's safety loop reporting that something is open, so please do not hold the reset button down.
When to call a technician. A fan that will not stop, repeated holds, or heat that cycles on and off every few minutes. Aurora Star Tech services boilers across Vaughan, Toronto and the GTA.
Applies to: Trinity Tft60, Tft85, Tft110, Tft155, Tft175, Tft200, Tft250, Tft300, Tft399
Questions about the NTI boiler
What is the Demand satisfied and shutdown on a NTI boiler?
This page covers what an NTI Trinity Tft boiler does at the end of a heating or hot water call, once the thermostat or tank has what it wanted.
Is it normal for my NTI boiler to do this?
A fan that keeps running for a short while after the flame goes out, pumps that continue briefly or stop when demand ends, and a quiet boiler between calls. The display returns to its summary page, ready for the next request.
Who can service my NTI boiler near me?
Aurora Star Tech Inc. repairs and services NTI boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.