Bosch boiler: Heating call, anti-cycle and pump post purge
When your thermostat asks for heat, a Bosch Greenstar 3A boiler fires, heats the water to a target temperature, then shuts down in a careful order. This page explains the pauses and extra pump running that surprise people.
How the Bosch boiler works: Heating call, anti-cycle and pump post purge
What this is. When your thermostat asks for heat, a Bosch Greenstar 3A boiler fires, heats the water to a target temperature, then shuts down in a careful order. This page explains the pauses and extra pump running that surprise people.
What happens, in order. A call for heat arrives from the control or thermostat. The pump behaves according to an installer setting: it may follow the control, start together with the burner, run all the time, or run only when needed. The burner fires and heats the supply water to its target. When the supply goes above target by a set margin (18 F as factory default), the burner stops. The fan then keeps running for about 30 seconds to clear the exhaust. An anti-cycle timer, 3 minutes as factory setting, blocks a quick restart so the boiler does not switch on and off repeatedly. After the call ends, the heating pump keeps running for about 3 minutes to carry the remaining heat to your radiators.
What is normal. A few minutes' wait before the burner relights, a fan that runs on after the flame goes out, and a pump that continues after the thermostat is satisfied.
Safe checks. Make sure the thermostat is above room temperature, the boiler's switch and the breaker are on, and the system pressure is in the normal range on the gauge.
When to call. If the boiler cycles every minute or two, never heats, or shows a fault code, Aurora Star Tech can adjust and service it for you.
Key times at a glance
| What | How long or how much |
|---|---|
| Anti-cycle time (3.b) | 0-15 min, default 3 min, 0 = off |
| Auto anti-cycle (3.A) | default off |
| Switching differential (3.C) | default 18 F (10 C) |
| Fan post purge (5.b) | 10-180 s, default 30 s |
| Heating pump post purge (9.F) | 1-10 min, default 3 min |
Applies to: Greenstar 3A series
Questions about the Bosch boiler
What is the Heating call, anti-cycle and pump post purge on a Bosch boiler?
When your thermostat asks for heat, a Bosch Greenstar 3A boiler fires, heats the water to a target temperature, then shuts down in a careful order. This page explains the pauses and extra pump running that surprise people.
Is it normal for my Bosch boiler to do this?
A few minutes' wait before the burner relights, a fan that runs on after the flame goes out, and a pump that continues after the thermostat is satisfied.
Who can service my Bosch boiler near me?
Aurora Star Tech Inc. repairs and services Bosch boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.