Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Bosch boiler: Heating call, anti-cycle and pump post purge

Updated · by Aurora Star Tech Inc.

When your thermostat asks for heat, a Bosch Greenstar 3A boiler fires, heats the water to a target temperature, then shuts down in a careful order. This page explains the pauses and extra pump running that surprise people.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the Bosch boiler works: Heating call, anti-cycle and pump post purge

What this is. When your thermostat asks for heat, a Bosch Greenstar 3A boiler fires, heats the water to a target temperature, then shuts down in a careful order. This page explains the pauses and extra pump running that surprise people.

What happens, in order. A call for heat arrives from the control or thermostat. The pump behaves according to an installer setting: it may follow the control, start together with the burner, run all the time, or run only when needed. The burner fires and heats the supply water to its target. When the supply goes above target by a set margin (18 F as factory default), the burner stops. The fan then keeps running for about 30 seconds to clear the exhaust. An anti-cycle timer, 3 minutes as factory setting, blocks a quick restart so the boiler does not switch on and off repeatedly. After the call ends, the heating pump keeps running for about 3 minutes to carry the remaining heat to your radiators.

What is normal. A few minutes' wait before the burner relights, a fan that runs on after the flame goes out, and a pump that continues after the thermostat is satisfied.

Safe checks. Make sure the thermostat is above room temperature, the boiler's switch and the breaker are on, and the system pressure is in the normal range on the gauge.

When to call. If the boiler cycles every minute or two, never heats, or shows a fault code, Aurora Star Tech can adjust and service it for you.

Key times at a glance

WhatHow long or how much
Anti-cycle time (3.b)0-15 min, default 3 min, 0 = off
Auto anti-cycle (3.A)default off
Switching differential (3.C)default 18 F (10 C)
Fan post purge (5.b)10-180 s, default 30 s
Heating pump post purge (9.F)1-10 min, default 3 min

Applies to: Greenstar 3A series

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the Bosch boiler

What is the Heating call, anti-cycle and pump post purge on a Bosch boiler?

When your thermostat asks for heat, a Bosch Greenstar 3A boiler fires, heats the water to a target temperature, then shuts down in a careful order. This page explains the pauses and extra pump running that surprise people.

Is it normal for my Bosch boiler to do this?

A few minutes' wait before the burner relights, a fan that runs on after the flame goes out, and a pump that continues after the thermostat is satisfied.

Who can service my Bosch boiler near me?

Aurora Star Tech Inc. repairs and services Bosch boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977