Bosch heat pump: Crankcase heater and reversing valve behaviour
Compressors dislike being started cold, so your Bosch IDS heat pump warms its compressor first and carefully shifts its heating and cooling valve. This page explains those quiet behind-the-scenes steps.
How the Bosch heat pump works: Crankcase heater and reversing valve behaviour
What this is. Compressors dislike being started cold, so your Bosch IDS heat pump warms its compressor first and carefully shifts its heating and cooling valve. This page explains those quiet behind-the-scenes steps.
What happens, in order. A small crankcase heater, which keeps the compressor oil warm, switches on when power is first applied if the unit is cool, and again after the compressor has sat idle for 3 hours in cold weather. It turns off once the unit is warm enough, or as soon as the compressor starts. The reversing valve, which swaps between heating and cooling, is switched on for heating and off for cooling. On the very first heat call after power returns, the unit runs in cooling mode for about 1 minute so enough pressure builds for the valve to move over. A pressure equalizer valve also balances the system before each compressor start.
What is normal. A short delay before the outdoor unit starts, a brief burst of cool air on the first heat call after a power cut or switch-on, and a unit that seems idle while its heater warms up. After a long cold shutdown, the unit should have power on with the thermostat off for at least 12 hours before it runs.
Safe checks. Do not switch the outdoor power off for the winter. Confirm the thermostat and breaker, and keep the outdoor unit clear of snow.
When to call. If the unit will not start after a long wait with power on, or you hear loud noises on starting, Aurora Star Tech can help.
Key times at a glance
| What | How long or how much |
|---|---|
| Heater on threshold | T5 below 53.6F |
| Heater off threshold | T5 60.8F or higher |
| Off-cycle trigger | Compressor off 3 h |
| Cold shutdown preheat | 12 h minimum |
| First heat call cooling run | About 1 min |
Applies to: Bosch IDS inverter heat pump condensing units
Questions about the Bosch heat pump
What is the Crankcase heater and reversing valve behaviour on a Bosch heat pump?
Compressors dislike being started cold, so your Bosch IDS heat pump warms its compressor first and carefully shifts its heating and cooling valve. This page explains those quiet behind-the-scenes steps.
Is it normal for my Bosch heat pump to do this?
A short delay before the outdoor unit starts, a brief burst of cool air on the first heat call after a power cut or switch-on, and a unit that seems idle while its heater warms up. After a long cold shutdown, the unit should have power on with the thermostat off for at least 12 hours before it runs.
Who can service my Bosch heat pump near me?
Aurora Star Tech Inc. repairs and services Bosch heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.