Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Trane air handler: Modular blower cooling call (single and two-stage)

Updated · by Aurora Star Tech Inc.

A Trane P0V0 modular blower is the indoor fan section that moves air for your cooling system. It has a small display that shows what it is doing. This page explains how it behaves during a cooling call, for both single-stage and two-stage systems.

Homeowner with a air handler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the Trane air handler works: Modular blower cooling call (single and two-stage)

What this is. A Trane P0V0 modular blower is the indoor fan section that moves air for your cooling system. It has a small display that shows what it is doing. This page explains how it behaves during a cooling call, for both single-stage and two-stage systems.

What happens, in order. When the thermostat calls for cooling, it signals both the outdoor unit and the blower. The outdoor unit starts its first stage of cooling, and the indoor blower ramps up gently to first-stage cooling airflow. The display alternates between CL1 and ARF. ARF is the calculated airflow, and you multiply the number by 10, so 080 means about 800 cfm. That reading takes about 1 to 2 minutes to settle. If the home needs more cooling, the thermostat asks for second stage, the outdoor unit steps up, the blower speeds up and the display shows CL2.

When cooling ends. The outdoor unit stops and the blower stops, unless the installer has set a blower off delay, which keeps the fan running a little longer. The display then returns to IDL, meaning idle. First-stage airflow is set by the installer from the outdoor unit menu: 80 percent for a two-stage system with one compressor, and 50 percent with two compressors.

What is normal. A slow fan start, changing fan speed, alternating letters and numbers on the display, and a fan that runs gently at first stage.

Safe checks. Replace the filter, check that vents and returns are open, and make sure the thermostat is in Cool.

When to call a technician. If the display shows an error beginning with e, such as e01, e6 or e12 to e18, or the blower won't start, write down the code and call Aurora Star Tech.

Key times at a glance

WhatHow long or how much
Airflow displayvalue x 10 (080 = 800 cfm)
Calculated airflow settle timeabout 1 to 2 min
First-stage airflow, 1 compressor80 percent
First-stage airflow, 2 compressors50 percent

Applies to: P0V0 modular blowers on air conditioning

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the Trane air handler

What is the Modular blower cooling call (single and two-stage) on a Trane air handler?

A Trane P0V0 modular blower is the indoor fan section that moves air for your cooling system. It has a small display that shows what it is doing. This page explains how it behaves during a cooling call, for both single-stage and two-stage systems.

Is it normal for my Trane air handler to do this?

A slow fan start, changing fan speed, alternating letters and numbers on the display, and a fan that runs gently at first stage.

Who can service my Trane air handler near me?

Aurora Star Tech Inc. repairs and services Trane air handlers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Air Handler Emergency

647-657-2977