Rinnai boiler: DHW run limit and heating restart
A Rinnai I-Series Plus is a combi boiler, which means one appliance provides both your radiator or in-floor heating and your hot tap water. When hot water is being used, it gets priority. This page explains how long that lasts and why heating may pause.
How the Rinnai boiler works: DHW run limit and heating restart
What this is. A Rinnai I-Series Plus is a combi boiler, which means one appliance provides both your radiator or in-floor heating and your hot tap water. When hot water is being used, it gets priority. This page explains how long that lasts and why heating may pause.
What happens, in order. When you open a hot tap, a small water flow turbine inside spins and tells the boiler that hot water is wanted. The boiler then keeps heating domestic hot water for as long as the tap stays open. To keep the house from going cold during a very long draw, there is a limit set by the installer. The usual setting is 120 minutes, and other choices are 60, 180 or unlimited. If hot water runs longer than the chosen limit, code 021 appears so the system does not stay on hot water while central heating waits.
Heating after hot water. If the thermostat is asking for heat while you shower, heating waits. After the tap closes, allow at least 3 minutes before heating restarts, and at least 5 minutes if Economy mode is on.
What is normal. Radiators or floors cooling slightly during a long bath fill, a pause of a few minutes before the heating pump and burner resume, and a different sound when switching between hot water and heating.
Safe checks. Wait the full few minutes before assuming heating has failed. Check the thermostat setting, the boiler's power switch and the pressure gauge, and write down any displayed code.
When to call a technician. Call if code 021 appears during normal showers, heating never resumes after the wait, or pressure drops. Aurora Star Tech services Rinnai boilers across the GTA.
Key times at a glance
| What | How long or how much |
|---|---|
| Parameter 18 A (default) | 120 min |
| Parameter 18 b | 60 min |
| Parameter 18 C | 180 min |
| Parameter 18 d | unlimited |
| Wait after DHW before heating | 3 min |
| Wait with Economy mode | 5 min |
Applies to: Rinnai I-Series Plus combi boilers
Questions about the Rinnai boiler
What is the DHW run limit and heating restart on a Rinnai boiler?
A Rinnai I-Series Plus is a combi boiler, which means one appliance provides both your radiator or in-floor heating and your hot tap water. When hot water is being used, it gets priority. This page explains how long that lasts and why heating may pause.
Is it normal for my Rinnai boiler to do this?
Radiators or floors cooling slightly during a long bath fill, a pause of a few minutes before the heating pump and burner resume, and a different sound when switching between hot water and heating.
Who can service my Rinnai boiler near me?
Aurora Star Tech Inc. repairs and services Rinnai boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.