Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Noritz tankless water heater: On-demand heating cycle

Updated · by Aurora Star Tech Inc.

Noritz premix tankless water heaters (the EZ, NRCR and CDV models) heat water only when you open a hot tap. Here is how that works.

Homeowner with a tankless water heater problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the Noritz tankless water heater works: On-demand heating cycle

What this is. Noritz premix tankless water heaters (the EZ, NRCR and CDV models) heat water only when you open a hot tap. Here is how that works.

What happens, in order. When hot water is drawn and the flow reaches the minimum, usually about half a gallon per minute, the fan starts and mixes air and gas. The gas valve opens and the igniter sparks. A flame rod then proves the flame. If no flame is found the display shows code 11, and if the flame is lost repeatedly, code 12. Once lit, the unit adjusts its burner to your flow, your set temperature and the incoming water temperature, so it reaches the set temperature quickly. When you close the tap, the burner shuts off.

Why flow matters. A very small trickle may not be enough to start the heater, which is why hot water can run cold at very low flow. The heat needed grows with flow and with how cold the incoming water is.

What is normal. A fan whirr and a few clicks before heat, a short delay of a few seconds, and fluctuations with very low flow.

Safe checks. Open the tap fully, check that the gas supply valve and power are on, and look at the display. Make sure the outdoor vent terminations are clear of snow, leaves and nests.

When to call a technician. Codes 11, 12, 14, 16, 20 or 90 (90 points to a restriction in the intake or exhaust) call for service. If you smell gas, leave and call from outside. Aurora Star Tech can help.

Key times at a glance

WhatHow long or how much
Minimum flow to stay onusually about 0.5 gpm
BTU demandgpm x temperature rise x 500

Applies to: Noritz premix tankless

Error codes linked to this step

Noritz code 11Noritz code 12Noritz code 14Noritz code 16Noritz code 20Noritz code 90

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the Noritz tankless water heater

What is the On-demand heating cycle on a Noritz tankless water heater?

Noritz premix tankless water heaters (the EZ, NRCR and CDV models) heat water only when you open a hot tap. Here is how that works.

Is it normal for my Noritz tankless water heater to do this?

A fan whirr and a few clicks before heat, a short delay of a few seconds, and fluctuations with very low flow.

Who can service my Noritz tankless water heater near me?

Aurora Star Tech Inc. repairs and services Noritz tankless water heaters in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977