KeepRite heat pump: Heat pump: time/temperature defrost and Quiet Shift 2
Heat pumps collect frost on the outdoor coil in winter, and KeepRite N4H4, R4H4, WCH4 and NXH5 models melt it with a timed defrost routine. This page explains how it works and the quieter "Quiet Shift 2" option.
How the KeepRite heat pump works: Heat pump: time/temperature defrost and Quiet Shift 2
What this is. Heat pumps collect frost on the outdoor coil in winter, and KeepRite N4H4, R4H4, WCH4 and NXH5 models melt it with a timed defrost routine. This page explains how it works and the quieter "Quiet Shift 2" option.
What happens, in order. A timer decides how often defrost can happen, with choices of 30, 60, 90 or 120 minutes. The timer only counts while the coil is cold enough, about 32 degrees Fahrenheit, and the compressor is running. When it finishes, the unit switches to something like cooling mode: the outdoor fan stops and the indoor electric backup heat comes on so you do not feel a cold draft. Defrost ends when the coil warms to about 65 degrees Fahrenheit, or after 10 minutes, whichever comes first. On newer aluminum-coil models, the first interval is as set and later ones adjust to how long defrosts take. With Quiet Shift 2, the compressor pauses for roughly a minute before and after the switch-over, which softens the noise you might otherwise hear.
What is normal. Steam and dripping water from the outdoor unit, a pause in the fan, cooler air for a few minutes, and a brief quiet moment from the compressor. Forced-defrost tests are technician-only.
Safe checks. Keep snow, ice and leaves away from the outdoor unit, with room around it. Check the filter and thermostat.
When to call. If the outdoor unit stays buried in ice for hours, defrost seems to run constantly or the house cools off, call Aurora Star Tech.
Key times at a glance
| What | How long or how much |
|---|---|
| Defrost interval | 30 / 60 / 90 / 120 min |
| Defrost start | about 32 F coil |
| Defrost end | about 65 F coil |
| Maximum defrost | 10 min |
| Quiet Shift 2 compressor-off | about 1 min at start and 1 min at end |
| Forced defrost pin hold | 5 s |
Applies to: KeepRite / ICP N4H4, R4H4, WCH4, NXH5 heat pumps
Questions about the KeepRite heat pump
What is the Heat pump: time/temperature defrost and Quiet Shift 2 on a KeepRite heat pump?
Heat pumps collect frost on the outdoor coil in winter, and KeepRite N4H4, R4H4, WCH4 and NXH5 models melt it with a timed defrost routine. This page explains how it works and the quieter "Quiet Shift 2" option.
Is it normal for my KeepRite heat pump to do this?
Steam and dripping water from the outdoor unit, a pause in the fan, cooler air for a few minutes, and a brief quiet moment from the compressor. Forced-defrost tests are technician-only.
Who can service my KeepRite heat pump near me?
Aurora Star Tech Inc. repairs and services KeepRite heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.