Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Rinnai air handler: Heating call, single-stage thermostat

Updated · by Aurora Star Tech Inc.

A Rinnai Canadian hydronic air handler heats your home with hot water. The hot water comes from a tankless unit or boiler, flows through a coil inside the air handler, and a blower pushes the warmed air through your ducts. Here is a single-stage thermostat call.

Homeowner with a air handler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the Rinnai air handler works: Heating call, single-stage thermostat

What this is. A Rinnai Canadian hydronic air handler heats your home with hot water. The hot water comes from a tankless unit or boiler, flows through a coil inside the air handler, and a blower pushes the warmed air through your ducts. Here is a single-stage thermostat call.

What happens, in order. When the thermostat calls for heat, the hot water circulating pump starts. After a short delay, normally 5 seconds, the blower starts. Hot water from the tankless unit or boiler moves through the coil, and the blower sends the warmed air into the ducts. Once the house is warm and the call ends, the blower keeps running for an off delay of 120 seconds by default, then stops.

Why the blower keeps going. That extra two minutes pushes the last of the heat out of the coil into your home instead of wasting it.

What is normal. A few seconds between the thermostat call and the sound of the blower, warm (not hot) air from the vents, and the blower running for a couple of minutes after the call ends. The air handler heats as fast as the hot water supplying it.

Safe checks. Replace the filter, open all supply vents and the return, set the thermostat to Heat above room temperature, and check the breaker. Make sure the tankless water heater or boiler that feeds it has power and is not showing a fault.

When to call a technician. If the blower runs but the air stays cool, the pump does not run, or there is water around the unit, contact Aurora Star Tech. We service hydronic air handlers across Vaughan, Toronto and the GTA.

Key times at a glance

WhatHow long or how much
Blower on delay (default)5 s
Blower off delay (default)120 s

Applies to: Rinnai Canadian hydronic air handler (heat pump and A/C versions)

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the Rinnai air handler

What is the Heating call, single-stage thermostat on a Rinnai air handler?

A Rinnai Canadian hydronic air handler heats your home with hot water. The hot water comes from a tankless unit or boiler, flows through a coil inside the air handler, and a blower pushes the warmed air through your ducts. Here is a single-stage thermostat call.

Is it normal for my Rinnai air handler to do this?

A few seconds between the thermostat call and the sound of the blower, warm (not hot) air from the vents, and the blower running for a couple of minutes after the call ends. The air handler heats as fast as the hot water supplying it.

Who can service my Rinnai air handler near me?

Aurora Star Tech Inc. repairs and services Rinnai air handlers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.