Rheem furnace: Two-stage heating cycle and staging
The Rheem RGPE two-stage furnace can run gently on low fire or harder on high fire. How it moves between the two depends on the thermostat it is paired with.
How the Rheem furnace works: Two-stage heating cycle and staging
What this is. The Rheem RGPE two-stage furnace can run gently on low fire or harder on high fire. How it moves between the two depends on the thermostat it is paired with.
What happens, in order. A heat call from the thermostat starts the cycle. The furnace confirms its airflow switches are open, then starts the inducer fan on high speed for a 30-second pre-purge. As the fan builds airflow, the switches close. The spark fires and the gas valve opens on low fire, and the ignition control hands over once it proves flame, with a maximum trial of 8 seconds. The gas stays on low for a 20-second warm-up before the blower takes over.
How staging works. With a two-stage thermostat, a first-stage call gives low gas and low blower speed, while a second-stage call gives high gas and high blower speed. With a single-stage thermostat, the furnace runs on low for 0 to 7 minutes depending on setup, then steps up to full firing.
When the call ends. If the call ends during any phase, the furnace shuts down at whatever rate it was running, and returns to its normal off cycle.
What is normal. A longer, quieter low-fire run on mild days, a step up in sound and airflow when it moves to high, and a short wait before the blower starts.
Safe checks. Check the thermostat, filter, breaker and furnace switch, and clear outdoor vent pipes of snow or nests.
When to call a technician. If the furnace never moves to high fire, short-cycles, or you have no heat, call Aurora Star Tech. Any gas smell means leaving the house and calling from outside.
Key times at a glance
| What | How long or how much |
|---|---|
| Pre-purge | 30 s |
| Trial for ignition | 8 s max |
| Warm-up on low rate before blower | 20 s |
| Single-stage thermostat low-to-high timer | 7 min |
Applies to: Rheem RGPE series
Questions about the Rheem furnace
What is the Two-stage heating cycle and staging on a Rheem furnace?
The Rheem RGPE two-stage furnace can run gently on low fire or harder on high fire. How it moves between the two depends on the thermostat it is paired with.
Is it normal for my Rheem furnace to do this?
A longer, quieter low-fire run on mild days, a step up in sound and airflow when it moves to high, and a short wait before the blower starts.
Who can service my Rheem furnace near me?
Aurora Star Tech Inc. repairs and services Rheem furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.