Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Kinghome heat pump: Defrost and oil return

Updated · by Aurora Star Tech Inc.

Kinghome Ultranixx heat pumps melt frost from the outdoor coil with a temperature-controlled defrost and occasionally run an oil-return routine. This page explains both.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the Kinghome heat pump works: Defrost and oil return

What this is. Kinghome Ultranixx heat pumps melt frost from the outdoor coil with a temperature-controlled defrost and occasionally run an oil-return routine. This page explains both.

What happens, in order. In heating, a sensor on the outdoor coil watches the temperature. When it drops to the preset defrost temperature, the reversing valve switches to cooling position and the outdoor fan stops. When the sensor reaches the preset stop temperature, defrost ends. The valve returns to heating and the compressor and fan restart. A technician can choose standard defrost, which is the default, or strong defrost for very cold conditions, which runs longer. Separately, after a long stretch at low speed, the unit raises the compressor speed for about 5 minutes to push oil back where it belongs. This keeps the compressor healthy. A forced defrost can also be started from the outdoor board's menu, but that is technician work.

What is normal. Steam from the outdoor unit, dripping water, a pause in warm indoor air, a change in compressor sound, and an occasional five-minute speed-up that lets the unit work harder for no obvious reason.

Safe checks. Keep snow, ice and leaves away from the outdoor unit with clear space around it, clean the filters and make sure the thermostat is in Heat.

When to call. If the unit stays iced over, runs defrost constantly or the home will not warm up, contact Aurora Star Tech and we will check the sensors and settings.

Key times at a glance

WhatHow long or how much
Oil return durationAbout 5 min
Menu idle timeout10 s
SW1 hold to enter debugAbout 5 s

Applies to: Kinghome Ultranixx ducted heat pump condensing units with air handlers

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the Kinghome heat pump

What is the Defrost and oil return on a Kinghome heat pump?

Kinghome Ultranixx heat pumps melt frost from the outdoor coil with a temperature-controlled defrost and occasionally run an oil-return routine. This page explains both.

Is it normal for my Kinghome heat pump to do this?

Steam from the outdoor unit, dripping water, a pause in warm indoor air, a change in compressor sound, and an occasional five-minute speed-up that lets the unit work harder for no obvious reason.

Who can service my Kinghome heat pump near me?

Aurora Star Tech Inc. repairs and services Kinghome heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977