Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Goodman-Amana-Daikin air conditioner: Communicating low and high stage cooling

Updated · by Aurora Star Tech Inc.

Goodman ComfortNet systems pair an ASXC, GSXC or DSXC air conditioner with an AVPTC air handler, and the two parts talk to each other digitally instead of through many separate wires. This page explains how a cooling call works with that conversation.

Homeowner with a air conditioner problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the Goodman-Amana-Daikin air conditioner works: Communicating low and high stage cooling

What this is. Goodman ComfortNet systems pair an ASXC, GSXC or DSXC air conditioner with an AVPTC air handler, and the two parts talk to each other digitally instead of through many separate wires. This page explains how a cooling call works with that conversation.

What happens, in order. When the thermostat asks for cooling, the air handler passes a low-stage request to the outdoor unit's control. The outdoor control sorts out its own start-up delays and asks the air handler for a low blower speed. The compressor and condenser fan start at low stage. If low stage cannot keep up with the heat, the control calls for high stage, the blower speeds up and the outdoor unit switches its compressor and fan to high. On hot days the system may even skip low stage and start on high. When the room is cool enough, the outdoor unit stops, and the air handler keeps its blower for any cool-down period. As a safety measure, each side stops by itself if the request for operation is not refreshed within 5 minutes, so a lost signal cannot leave the system running unattended.

What is normal. Quiet, longer low-stage cycles, a blower speed that changes by itself, and a short delay before the outdoor unit starts.

Safe checks. Make sure the thermostat is on Cool, the filter is clean, vents are open, the outdoor unit is clear, and the breaker is on. One reset of the power for ten seconds is fine.

When to call a technician. Communication or fault messages on the thermostat, an outdoor unit that never starts, or poor cooling. Aurora Star Tech can service communicating systems.

Key times at a glance

WhatHow long or how much
Request refresh timeout5 min

Applies to: Goodman ComfortNet ASXC / GSXC / DSXC with AVPTC / MBVC air handlers

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the Goodman-Amana-Daikin air conditioner

What is the Communicating low and high stage cooling on a Goodman-Amana-Daikin air conditioner?

Goodman ComfortNet systems pair an ASXC, GSXC or DSXC air conditioner with an AVPTC air handler, and the two parts talk to each other digitally instead of through many separate wires. This page explains how a cooling call works with that conversation.

Is it normal for my Goodman-Amana-Daikin air conditioner to do this?

Quiet, longer low-stage cycles, a blower speed that changes by itself, and a short delay before the outdoor unit starts.

Who can service my Goodman-Amana-Daikin air conditioner near me?

Aurora Star Tech Inc. repairs and services Goodman-Amana-Daikin air conditioners in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service