Goodman-Amana-Daikin furnace: Two-stage gas heat call with ramped blower

Updated · by Aurora Star Tech Inc.

A Goodman or Amana GMVC95 or GMVC9 is a two-stage furnace with a variable-speed blower that eases up and down in speed instead of switching on abruptly. This page walks through a heat call.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the Goodman-Amana-Daikin furnace works: Two-stage gas heat call with ramped blower

What this is. A Goodman or Amana GMVC95 or GMVC9 is a two-stage furnace with a variable-speed blower that eases up and down in speed instead of switching on abruptly. This page walks through a heat call.

What happens, in order. The control checks its safety circuits, then runs the inducer fan on high for a 15-second purge. It then steps down to low speed, confirms airflow, and warms the igniter. The gas valve opens at the end of that warm-up, and gas keeps flowing only while a flame is detected. A mild call for heat stays on low fire, and a bigger call moves the furnace up to high. About 30 seconds after ignition, the blower starts and takes another 30 seconds to ramp up to full speed, which is why the air feels gentle at first. If the furnace steps from low to high, everything switches to high right away. When the call ends, the gas closes, the inducer runs a final 15 seconds, and the blower keeps going for the off delay, anywhere from 90 to 180 seconds, ramping down over the last 30.

If there is no flame. After three failed tries in one call, the furnace locks out and shows E0. It resets itself after one hour.

What is normal. Gradual air, long low-fire cycles, and a blower that continues after the flame is out.

Safe checks. Replace a dirty filter, check the thermostat and breaker, and clear the outside vent pipes of snow. One power reset is fine. Any gas smell means leaving the house and calling from outside.

When to call a technician. An E0 lockout that returns, or heat that quits. Aurora Star Tech can help.

Key times at a glance

WhatHow long or how much
Pre-purge (inducer high)15 s
Blower on delay30 s
Blower ramp up / down30 s
Post-purge15 s
Heat off delay90, 120, 150 or 180 s (60 to 150 s remaining after a high-heat call)
Ignition attempts per call3, then lockout
Lockout auto reset1 hour

Applies to: Goodman GMVC95 two-stage variable-speed furnaces (upflow and counterflow *CVC9 family)

Error codes linked to this step

Goodman code E0

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the Goodman-Amana-Daikin furnace

What is the Two-stage gas heat call with ramped blower on a Goodman-Amana-Daikin furnace?

A Goodman or Amana GMVC95 or GMVC9 is a two-stage furnace with a variable-speed blower that eases up and down in speed instead of switching on abruptly. This page walks through a heat call.

Is it normal for my Goodman-Amana-Daikin furnace to do this?

Gradual air, long low-fire cycles, and a blower that continues after the flame is out.

Who can service my Goodman-Amana-Daikin furnace near me?

Aurora Star Tech Inc. repairs and services Goodman-Amana-Daikin furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977