Updated · by Aurora Star Tech Inc.

A KeepRite 9MXE is a single-stage, 95% efficient gas furnace, meaning it burns at one steady rate. This page covers the blower timing during a normal heating cycle, so you know why warm air takes a moment to arrive and why the fan keeps going after the burners stop.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the KeepRite furnace works: Single-stage 95% furnace: heating cycle and blower delays

What this is. A KeepRite 9MXE is a single-stage, 95% efficient gas furnace, meaning it burns at one steady rate. This page covers the blower timing during a normal heating cycle, so you know why warm air takes a moment to arrive and why the fan keeps going after the burners stop.

What happens, in order. Once the flame is proven, the furnace does not push air right away. It waits 25 seconds after the gas valve opens, so the heat exchanger has a chance to warm up and the first air you feel is already warm. The blower then starts at its heating speed, and any connected electronic air cleaner comes on with it. When the thermostat is satisfied, the gas valve closes, the humidifier connection shuts off, and the inducer fan runs 15 seconds longer to clear leftover gases. The main blower continues for a heat-off delay while it collects the last of the warmth from the furnace. That delay comes set at 2 minutes from the factory, and a technician can change it to 90, 150 or 180 seconds.

What is normal. A pause of about half a minute after the flame lights before warm air arrives, and the blower still running a couple of minutes after the burners go out.

Safe checks. A clean filter keeps airflow healthy and may shorten cycles. Check that vents and returns are open and unblocked, and that the thermostat is on Heat.

When to call. If the blower never starts after the burner lights, the air stays cold or the furnace shuts off before the house warms, book a visit with Aurora Star Tech.

Key times at a glance

WhatHow long or how much
Blower-on delay25 s
Inducer post-purge15 s
Heat-off delay options90 / 120 / 150 / 180 s
Heat-off delay factory120 s

Applies to: KeepRite / ICP (F-G)9MXE single-stage 95% furnace (KeepRite G9MXE)

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the KeepRite furnace

What is the Single-stage 95% furnace: heating cycle and blower delays on a KeepRite furnace?

A KeepRite 9MXE is a single-stage, 95% efficient gas furnace, meaning it burns at one steady rate. This page covers the blower timing during a normal heating cycle, so you know why warm air takes a moment to arrive and why the fan keeps going after the burners stop.

Is it normal for my KeepRite furnace to do this?

A pause of about half a minute after the flame lights before warm air arrives, and the blower still running a couple of minutes after the burners go out.

Who can service my KeepRite furnace near me?

Aurora Star Tech Inc. repairs and services KeepRite furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.