Rinnai furnace: Normal start and heating
The Rinnai EX DT is a direct-vent room furnace, which heats a room without ductwork.
How the Rinnai furnace works: Normal start and heating
What this is. The Rinnai EX DT is a direct-vent room furnace, which heats a room without ductwork.
What happens, in order. Pressing ON/OFF on the control panel lights the display and turns the ON lamp green. The combustion fan starts first and runs for roughly 15 to 18 seconds, pushing fresh air through the burner area. A spark then lights the main burner. Once the furnace confirms there is a flame, the ON lamp turns red and the spark stops. After the furnace warms up, the room convection fan starts on its own to push warm air into the room. From there, the thermostat adjusts the burner and fan between their low and high settings to hold the temperature you chose. The setting range is 60 to 80 °F in 2 degree steps, or you can pick simple low or high.
If the power goes out. The furnace restarts by itself when power returns.
What is normal. A short delay, a whirring fan and a clicking spark before the flame appears, a lamp that is green first and red once the flame is established, and a fan that changes speed as the furnace adjusts to the room.
Safe checks. Keep furniture, curtains and anything that can burn well away from the front of the unit, and make sure the outside vent terminal is not blocked by snow or leaves.
When to call a technician. If you see code 11, the furnace does not light or you smell gas, leave the house, call from outside, and contact Aurora Star Tech.
Key times at a glance
| What | How long or how much |
|---|---|
| Forced combustion before control logic takes over | about 15 to 18 s |
| Temperature setting range | 60 to 80 F in 2 F steps (or L / H) |
Applies to: Rinnai EX08DT, EX11DT, EX17DT, EX22DT direct-vent room furnaces
Questions about the Rinnai furnace
What is the Normal start and heating on a Rinnai furnace?
The Rinnai EX DT is a direct-vent room furnace, which heats a room without ductwork.
Is it normal for my Rinnai furnace to do this?
A short delay, a whirring fan and a clicking spark before the flame appears, a lamp that is green first and red once the flame is established, and a fan that changes speed as the furnace adjusts to the room.
Who can service my Rinnai furnace near me?
Aurora Star Tech Inc. repairs and services Rinnai furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.