KeepRite heat pump: Heat pump with 5-minute compressor delay: cooling and heating start

Updated · by Aurora Star Tech Inc.

To protect the compressor, KeepRite Performance Series heat pumps will not start it until a 5-minute timer has run out. This page explains that delay and what a normal start looks like for cooling and heating.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the KeepRite heat pump works: Heat pump with 5-minute compressor delay: cooling and heating start

What this is. To protect the compressor, KeepRite Performance Series heat pumps will not start it until a 5-minute timer has run out. This page explains that delay and what a normal start looks like for cooling and heating.

What happens, in order. When power first returns to the system, a 5-minute timer starts, and the compressor will not run until it ends. On a cooling call, the thermostat shifts the reversing valve into cooling and sends signals for the outdoor unit and indoor blower. The control passes the call along through its safety devices, and if the compressor has been off 5 minutes, the contactor closes and the outdoor fan and compressor start. A heating call works the same way but without the reversing valve signal; the defrost logic is armed and the same 5-minute rule applies. When the call is satisfied, the compressor and fan stop and the 5-minute timer starts over. After a power interruption, the next cycle also waits 5 minutes. With ICP thermostats, the reversing valve remains in cooling position until the thermostat goes to heat or off.

What is normal. The indoor fan running while the outdoor unit waits, a delay of up to five minutes after a power flicker or quick thermostat change, and a restart that seems slow after shutting the system off and on.

Safe checks. Wait the full five minutes before deciding something is wrong. Check the thermostat mode and setpoint, filter and breaker, and keep the outdoor unit clear.

When to call. If the outdoor unit still has not started after ten minutes, or it keeps stopping and starting, contact Aurora Star Tech.

Key times at a glance

WhatHow long or how much
Compressor time delay5 min

Applies to: KeepRite / ICP / Tempstar / Heil Performance Series split heat pumps (defrost control Fast #1174185)

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the KeepRite heat pump

What is the Heat pump with 5-minute compressor delay: cooling and heating start on a KeepRite heat pump?

To protect the compressor, KeepRite Performance Series heat pumps will not start it until a 5-minute timer has run out. This page explains that delay and what a normal start looks like for cooling and heating.

Is it normal for my KeepRite heat pump to do this?

The indoor fan running while the outdoor unit waits, a delay of up to five minutes after a power flicker or quick thermostat change, and a restart that seems slow after shutting the system off and on.

Who can service my KeepRite heat pump near me?

Aurora Star Tech Inc. repairs and services KeepRite heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.