Carrier heat pump: Variable-speed unit: low pressure protection and lockout
The Carrier Infinity variable-speed heat pump also watches for pressure that drops too low, such as when the system is struggling to take in heat. This page explains the pause, retry and lockout.
How the Carrier heat pump works: Variable-speed unit: low pressure protection and lockout
What this is. The Carrier Infinity variable-speed heat pump also watches for pressure that drops too low, such as when the system is struggling to take in heat. This page explains the pause, retry and lockout.
What happens, in order. If a pressure sensor reads below the set limits, code 32 appears and the compressor stops. After 6 minutes, if the system is still being asked for heat or cooling and pressure has come back up, it restarts and clears the code. If pressure has not recovered at six minutes, the outdoor fan is turned off, and the unit restarts whenever pressure recovers later. A third drop in a row below the no-operation level locks the unit out for 4 hours and shows code 83. The trip counter resets after 15 minutes of good running.
What is normal. A one-off code 32 in very cold weather that clears after about six minutes and the unit running normally again.
Safe checks. Check the filter and open all vents, clear snow and debris from the outdoor unit, and confirm the thermostat setting. You may switch the system off at the thermostat for a few minutes and then back on once.
When to call. Code 83, a code 32 that comes back, ice on the pipes or poor performance can signal a refrigerant problem that needs a licensed technician. Aurora Star Tech can help.
Key times at a glance
| What | How long or how much |
|---|---|
| Retry delay | 6 min |
| Lockout time | 4 hours |
| Trips to lockout | 3 in a row |
| Counter reset | 15 min of good running |
Applies to: Carrier Infinity 25VNA8 variable-speed heat pump and 24VNA9 variable-speed air conditioner
Error codes linked to this step
Carrier code 32Carrier code 83
Questions about the Carrier heat pump
What is the Variable-speed unit: low pressure protection and lockout on a Carrier heat pump?
The Carrier Infinity variable-speed heat pump also watches for pressure that drops too low, such as when the system is struggling to take in heat. This page explains the pause, retry and lockout.
Is it normal for my Carrier heat pump to do this?
A one-off code 32 in very cold weather that clears after about six minutes and the unit running normally again.
Who can service my Carrier heat pump near me?
Aurora Star Tech Inc. repairs and services Carrier heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.