Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Bosch air handler: Blower control: anti-cold-air delay and heating fan delay

Updated · by Aurora Star Tech Inc.

Your Bosch IDS air handler does not simply blow the moment heat is requested. It controls the blower speed and start time so you are not hit with cold air. This page explains how that works.

Homeowner with a air handler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the Bosch air handler works: Blower control: anti-cold-air delay and heating fan delay

What this is. Your Bosch IDS air handler does not simply blow the moment heat is requested. It controls the blower speed and start time so you are not hit with cold air. This page explains how that works.

What happens, in order. The thermostat sets the speed. A stage 1 call gives low speed, stage 2 gives high speed, a fan-only call gives low speed, and electric heat runs the blower on high. In one setup option the air handler holds the blower off until its indoor coil has warmed up, from below about 82 F to about 89.6 F. That wait ends if the heater kit starts, the call ends, or after 15 minutes. If the conditions linger for 2 minutes, the blower starts at first-stage speed anyway. In the other setup option the blower simply starts after a fixed 90 seconds.

What is normal. A minute or more of quiet after the thermostat calls for heat, then warm air building up. The wait avoids a cold draft on your skin.

Safe checks. Make sure the thermostat is set to Heat, replace a dirty filter and keep supply vents and return grilles open.

When to call. If the blower never starts, or runs only on high, Aurora Star Tech can check the settings and wiring. These options are set by the installer, so please do not adjust anything inside the unit yourself.

Key times at a glance

WhatHow long or how much
Fan delay (SW6-3 OFF)90 s
Anti-cold-air entry coil tempBelow 82.4F
Anti-cold-air exit coil temp89.6F or higher
Anti-cold-air maximum15 min
Forced first stage after120 s

Applies to: Bosch IDS Premium air handlers

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the Bosch air handler

What is the Blower control: anti-cold-air delay and heating fan delay on a Bosch air handler?

Your Bosch IDS air handler does not simply blow the moment heat is requested. It controls the blower speed and start time so you are not hit with cold air. This page explains how that works.

Is it normal for my Bosch air handler to do this?

A minute or more of quiet after the thermostat calls for heat, then warm air building up. The wait avoids a cold draft on your skin.

Who can service my Bosch air handler near me?

Aurora Star Tech Inc. repairs and services Bosch air handlers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Air Handler Emergency

647-657-2977