If a York TM9V or M9V furnace does not light cleanly, it does not keep trying forever. It has a set routine of retries and lockouts, and this page explains it in plain terms.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the York furnace works: Furnace ignition retry and lockout

What this is. If a York TM9V or M9V furnace does not light cleanly, it does not keep trying forever. It has a set routine of retries and lockouts, and this page explains it in plain terms.

What happens, in order. After the gas valve opens, the furnace allows 7 seconds to see a flame. If there is none, the valve closes and a retry begins. During a retry the vent motor clears the chamber for 15 seconds and the igniter warms longer, 27 seconds instead of 17. If flame is lost within the first 2 seconds of its 10 second settling time, that also starts a retry. After three retries in one call for heat, the furnace shuts down for one hour, shown by 7 red flashes, and then tries a normal cycle again if heat is still wanted.

Flame lost while running. The furnace senses this in about a second, closes the gas valve, purges for 15 seconds and recycles. Five flame losses in one call lead to a 60 minute lockout with 8 red flashes. If the pressure switch opens four times in one call, a one hour lockout with 6 red flashes follows.

After a power blip. If power is lost for a split second, the gas valve closes and the ignition sequence restarts immediately when power returns.

What is normal. An occasional retry after a long idle period. A soft lockout resets itself after an hour, while a hard lockout needs the power turned off and on.

Safe checks. Check the filter, thermostat and breaker, clear the outdoor pipes, and make one power reset only.

When to call a technician. Repeated flashes mean you should call Aurora Star Tech.

Key times at a glance

WhatHow long or how much
Flame prove time7 s
Flame stabilization10 s
Inter-purge on retry15 s
Warm-up on retry27 s
Retries before lockout3
Soft lockout1 hour
Recycles before lockout4

Applies to: TM9V and M9V furnaces

Error codes linked to this step

York code 7 red flashesYork code 8 red flashesYork code 6 red flashesYork code 1 red flashYork code 10 red flashes

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the York furnace

What is the Furnace ignition retry and lockout on a York furnace?

If a York TM9V or M9V furnace does not light cleanly, it does not keep trying forever. It has a set routine of retries and lockouts, and this page explains it in plain terms.

Is it normal for my York furnace to do this?

An occasional retry after a long idle period. A soft lockout resets itself after an hour, while a hard lockout needs the power turned off and on.

Who can service my York furnace near me?

Aurora Star Tech Inc. repairs and services York furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977