Lennox furnace: Single-stage furnace ignition retries and watchguard
If your Lennox EL195UHNE or ML180UHEK furnace does not light on the first try, it does not give up and it does not keep trying forever. This page describes the retry routine and the pause that follows repeated failures.
How the Lennox furnace works: Single-stage furnace ignition retries and watchguard
What this is. If your Lennox EL195UHNE or ML180UHEK furnace does not light on the first try, it does not give up and it does not keep trying forever. This page describes the retry routine and the pause that follows repeated failures.
What happens, in order. After the igniter has warmed, the gas valve opens for a 4-second trial. If the flame sensor does not confirm a flame in that time, the valve closes. The furnace then clears the chamber and warms the igniter again for 35 seconds before the next try. It makes up to five trials in total, counting the first. If all five fail, the furnace enters a protective mode called watchguard flame failure, and the gas valve stays shut. After a 60-minute reset period, it starts the whole sequence again from the beginning on its own. A flame that lights and then drops out partway through a heat call is counted as a recycle, and too many recycles also trigger watchguard. A weak flame signal can be flagged separately by a flash code, which often means the flame sensor needs cleaning.
What is normal. One or two attempts on a cold start, a short pause between tries, and the occasional clicking you hear as the igniter cycles.
Safe checks. Replace the filter, check the thermostat and breaker, clear snow and nests from the outdoor intake and exhaust pipes, and close the furnace door. A single power reset is reasonable. Do not open the burner area yourself.
When to call. Heat that fails for an hour or more, flash codes that return, or a gas smell. If you smell gas, go outside and call from there. Aurora Star Tech can clean and test the ignition parts.
Key times at a glance
| What | How long or how much |
|---|---|
| Trials for ignition | 5 total |
| Time between trials | 35 s inter-purge and warm-up |
| Watchguard reset | 60 min |
Applies to: EL195UHNE, ML180UHEK
Questions about the Lennox furnace
What is the Single-stage furnace ignition retries and watchguard on a Lennox furnace?
If your Lennox EL195UHNE or ML180UHEK furnace does not light on the first try, it does not give up and it does not keep trying forever. This page describes the retry routine and the pause that follows repeated failures.
Is it normal for my Lennox furnace to do this?
One or two attempts on a cold start, a short pause between tries, and the occasional clicking you hear as the igniter cycles.
Who can service my Lennox furnace near me?
Aurora Star Tech Inc. repairs and services Lennox furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.