Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

KeepRite air conditioner: Split A/C: pressure switch and thermal cutout protection and lockout

Updated · by Aurora Star Tech Inc.

Your KeepRite C4A3, H4A3, T4A3 or CXA6 air conditioner has built-in safeguards that shut the compressor down if pressure, temperature or power go outside safe limits. This page explains the protections and what the codes mean in plain terms.

Homeowner with a air conditioner problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the KeepRite air conditioner works: Split A/C: pressure switch and thermal cutout protection and lockout

What this is. Your KeepRite C4A3, H4A3, T4A3 or CXA6 air conditioner has built-in safeguards that shut the compressor down if pressure, temperature or power go outside safe limits. This page explains the protections and what the codes mean in plain terms.

What happens, in order. If a high or low pressure switch opens, the control stops the compressor right away while the outdoor fan keeps running for 15 minutes, and the board shows code 31 for high or 32 for low. If the compressor's built-in thermal cutout trips, the fan keeps going, the control waits 15 minutes, then tries to restart (code 72). That code clears after a successful restart. If any of those protections trip three cycles in a row, the unit locks out for 4 hours (codes 82, 83 and 84), or until the control power is cycled. Other codes point to electrical conditions: 73 means the compressor contactor appears stuck closed, 74 means power is not reaching the compressor at start-up, and 46 means the control power dropped too low for a few seconds, so the compressor and fan wait until it recovers.

What is normal. Nothing here is routine; these are fault protections. A single trip on a very hot day that restarts itself is usually harmless.

Safe checks. Replace the filter, make sure the outdoor coil is clear of cottonwood, grass and leaves, and the vents are open. You may turn the power off for a minute and back on once.

When to call. Any of these codes appearing more than once, or the system locked out for hours. Aurora Star Tech can find the cause.

Key times at a glance

WhatHow long or how much
Fan run after trip15 min
Thermal cutout restart wait15 min
Consecutive trips to lockout3
Lockout time4 hours
Brown-out cutoutunder 15.5 V for 4 s
Brown-out recover17.5 V

Applies to: KeepRite / ICP C4A3, H4A3, T4A3, CXA6 R-410A split air conditioners

Error codes linked to this step

KeepRite code 31KeepRite code 46KeepRite code 72KeepRite code 73KeepRite code 74KeepRite code 82KeepRite code 83KeepRite code 84

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the KeepRite air conditioner

What is the Split A/C: pressure switch and thermal cutout protection and lockout on a KeepRite air conditioner?

Your KeepRite C4A3, H4A3, T4A3 or CXA6 air conditioner has built-in safeguards that shut the compressor down if pressure, temperature or power go outside safe limits. This page explains the protections and what the codes mean in plain terms.

Is it normal for my KeepRite air conditioner to do this?

Nothing here is routine; these are fault protections. A single trip on a very hot day that restarts itself is usually harmless.

Who can service my KeepRite air conditioner near me?

Aurora Star Tech Inc. repairs and services KeepRite air conditioners in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977