Some homes pair a KeepRite 9MXE, 9MXT or 9MAE furnace with a heat pump, using the furnace as backup on very cold days. This is called dual fuel. This page explains why the furnace blower behaves a little differently in that setup.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the KeepRite furnace works: Furnace used with a heat pump (dual fuel blower timing)

What this is. Some homes pair a KeepRite 9MXE, 9MXT or 9MAE furnace with a heat pump, using the furnace as backup on very cold days. This is called dual fuel. This page explains why the furnace blower behaves a little differently in that setup.

What happens, in order. When the furnace sees a call for heat at the same time as a signal from the heat pump, it adjusts its blower timing. The goal is to stop the air in your ducts from turning cold when the heat pump goes into defrost. The blower is brought on at the matching cooling or heat speed and stays on while the furnace purges its chamber. It then drops out for about 24 seconds (25 on the 9MAE, once the burners light) before coming back on at heat speed, giving the heat exchanger a moment to warm. When the heat call ends, the inducer finishes its normal post-purge and the blower follows whatever heat pump signal remains, using cool speed or low-cool speed depending on the system. On the two-stage furnace, it switches to cool speed after a short 3-second delay. If everything shuts off together, the blower runs the selected off-delay, and if the thermostat fan is on it settles at continuous fan speed.

What is normal. Blower speed changes, a short quiet gap of about 24 seconds, and slightly cooler air for a moment while the heat pump defrosts.

Safe checks. Check the filter, keep the outdoor unit clear of snow, and confirm the thermostat is set up for your system.

When to call. Persistently cold air during heat, or the furnace never taking over, calls for Aurora Star Tech.

Key times at a glance

WhatHow long or how much
Blower dropout in heat cycle24 s (9MXE, 9MXT); 25 s (9MAE)
Speed change after W drops (two-stage)3 s

Applies to: KeepRite / ICP (F-G)9MXE single-stage 95% furnace (KeepRite G9MXE); KeepRite / ICP (F-G)9MXT two-stage 95% furnace (KeepRite G9MXT); ICP (F-G)9MAE modulating 95% furnace

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the KeepRite furnace

What is the Furnace used with a heat pump (dual fuel blower timing) on a KeepRite furnace?

Some homes pair a KeepRite 9MXE, 9MXT or 9MAE furnace with a heat pump, using the furnace as backup on very cold days. This is called dual fuel. This page explains why the furnace blower behaves a little differently in that setup.

Is it normal for my KeepRite furnace to do this?

Blower speed changes, a short quiet gap of about 24 seconds, and slightly cooler air for a moment while the heat pump defrosts.

Who can service my KeepRite furnace near me?

Aurora Star Tech Inc. repairs and services KeepRite furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.