Kinghome heat pump: Compressor, expansion valve and fan startup/stop rules
Kinghome Ultranixx heat pumps are built to protect the compressor and run well in very hot or cold weather. This page explains the start-up and shutdown habits that can look odd but are completely intentional.
How the Kinghome heat pump works: Compressor, expansion valve and fan startup/stop rules
What this is. Kinghome Ultranixx heat pumps are built to protect the compressor and run well in very hot or cold weather. This page explains the start-up and shutdown habits that can look odd but are completely intentional.
What happens, in order. When cooling or heating is called for, the indoor fan runs for a while before the compressor starts, so air is already moving. On the very first power-up, the electronic expansion valve resets itself, and a rattling or ticking sound is normal while it does. Before the compressor starts, that valve opens to a preset position. After starting, the compressor must run for a minimum time, and after stopping it must rest for several minutes before it can restart. The outdoor fan runs in ten speed steps, from 1 at the lowest to 10 at the highest, which lets the unit cool in low outdoor temperatures and heat in high ones; it does not run at all in fan-only mode. In heating, the reversing valve switches a short time after heating starts, and when heating stops it stays energized briefly before letting go.
What is normal. A rattling noise right after power returns, an indoor fan that starts before the outdoor unit, an outdoor fan that changes speed with the weather, and a rest of several minutes before restarting.
Safe checks. Wait several minutes after any stop before deciding the unit is not working, clean the filters, check the breaker and keep the outdoor unit clear.
When to call. If the outdoor unit fails to start after ten minutes, a code appears or the noise continues, book Aurora Star Tech.
Applies to: Kinghome Ultranixx ducted heat pump condensing units with air handlers
Questions about the Kinghome heat pump
What is the Compressor, expansion valve and fan startup/stop rules on a Kinghome heat pump?
Kinghome Ultranixx heat pumps are built to protect the compressor and run well in very hot or cold weather. This page explains the start-up and shutdown habits that can look odd but are completely intentional.
Is it normal for my Kinghome heat pump to do this?
A rattling noise right after power returns, an indoor fan that starts before the outdoor unit, an outdoor fan that changes speed with the weather, and a rest of several minutes before restarting.
Who can service my Kinghome heat pump near me?
Aurora Star Tech Inc. repairs and services Kinghome heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.