Carrier furnace: Single-stage 80% furnace: ignition sequence and retries
A Carrier 58SB single-stage furnace follows a careful light-up routine each time the thermostat asks for heat, and it tries again a few times if the flame does not catch. This page explains each step so the pauses and clicks make sense.
How the Carrier furnace works: Single-stage 80% furnace: ignition sequence and retries
What this is. A Carrier 58SB single-stage furnace follows a careful light-up routine each time the thermostat asks for heat, and it tries again a few times if the flame does not catch. This page explains each step so the pauses and clicks make sense.
What happens, in order. The control checks itself, then starts the inducer fan, which clears the burner area. Once the fan is up to speed and a safety switch proves airflow, a 15 second pre-purge runs. The hot surface igniter then glows for 17 seconds, the gas valve opens, and a 2 second window starts 5 seconds later for the furnace to prove a flame. If it does, the gas valve stays open and the blower starts after its delay. If there is no flame, the gas valve closes and the control repeats the routine, with four tries in total. After the fourth failure it goes into lockout, and it clears by itself after 3 hours, or after power to the furnace is switched off and on. If it ever sees flame when it should not, it locks out gas heat and keeps the inducer fan running.
What is normal. Humming, clicking and a quiet wait of well under a minute before you feel warm air.
Safe checks. Replace a clogged filter, confirm the thermostat is in Heat, and check the breaker and furnace switch. You may turn the furnace power off for ten seconds and back on once. Clear snow from outdoor vent pipes.
When to call. If codes 13, 14, 21, 22, 23 or 45 appear, or you smell gas (leave the house and call from outside), contact Aurora Star Tech.
Key times at a glance
| What | How long or how much |
|---|---|
| Prepurge | 15 s |
| Igniter warm-up | 17 s |
| Flame proving | 2 s (starts 5 s after gas valve opens) |
| Ignition trials | 4 total |
| Lockout auto-reset | 3 hours |
Applies to: Carrier 58SB0A / 58SB1A 80% single-stage gas furnace
Error codes linked to this step
Carrier code 13Carrier code 14Carrier code 21Carrier code 22Carrier code 23Carrier code 45
Questions about the Carrier furnace
What is the Single-stage 80% furnace: ignition sequence and retries on a Carrier furnace?
A Carrier 58SB single-stage furnace follows a careful light-up routine each time the thermostat asks for heat, and it tries again a few times if the flame does not catch. This page explains each step so the pauses and clicks make sense.
Is it normal for my Carrier furnace to do this?
Humming, clicking and a quiet wait of well under a minute before you feel warm air.
Who can service my Carrier furnace near me?
Aurora Star Tech Inc. repairs and services Carrier furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.