Lennox heat pump: Heat pump cooling call
A Lennox ML14KP1 or EL16KP1 heat pump, which uses the newer R-454B refrigerant, cools your home by moving heat outdoors. Cooling is one of two directions the same machine can run. This page explains what happens each time the thermostat asks for cooling.
How the Lennox heat pump works: Heat pump cooling call
What this is. A Lennox ML14KP1 or EL16KP1 heat pump, which uses the newer R-454B refrigerant, cools your home by moving heat outdoors. Cooling is one of two directions the same machine can run. This page explains what happens each time the thermostat asks for cooling.
What happens, in order. When you set the thermostat to Cool, a valve inside the outdoor unit (the reversing valve) shifts into its cooling position. When the thermostat then calls for cooling, a contactor, which is a heavy-duty switch, closes and the compressor and the outdoor fan start together. When the house reaches the temperature you set, the call ends and both stop right away.
The five-minute wait. The outdoor unit's control board holds a five-minute delay before it will start the compressor again. It applies after the unit first gets power, after a safety shutdown, and at the end of every cooling call. Technicians can skip this wait with a test setting, but it is there to protect the compressor.
What is normal. The indoor fan running while the outdoor unit waits, a pause of up to five minutes after switching off and on, and the outdoor fan and compressor stopping together as soon as the room is cool.
Safe checks. Confirm the thermostat is set to Cool and below room temperature. Check the breaker and the outdoor disconnect, replace a dirty filter, and keep plants, snow and debris away from the outdoor unit. Wait the full five minutes before deciding it will not start.
When to call a technician. The control board has indicator lights that a technician reads for low pressure, high pressure and sensor faults. If the outdoor unit still does not run after ten minutes, or keeps stopping, Aurora Star Tech can help.
Key times at a glance
| What | How long or how much |
|---|---|
| Anti-short-cycle delay | 5 min |
Applies to: ML14KP1 and EL16KP1 heat pumps (R-454B)
Questions about the Lennox heat pump
What is the Heat pump cooling call on a Lennox heat pump?
A Lennox ML14KP1 or EL16KP1 heat pump, which uses the newer R-454B refrigerant, cools your home by moving heat outdoors. Cooling is one of two directions the same machine can run. This page explains what happens each time the thermostat asks for cooling.
Is it normal for my Lennox heat pump to do this?
The indoor fan running while the outdoor unit waits, a pause of up to five minutes after switching off and on, and the outdoor fan and compressor stopping together as soon as the room is cool.
Who can service my Lennox heat pump near me?
Aurora Star Tech Inc. repairs and services Lennox heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.