Goodman furnace: Cooling airflow ramping profiles A to D
Goodman ACVC96, AMVC96, GCVC96 and GMVC96 furnaces have a variable-speed blower that can ease into cooling instead of blasting on at full speed. This page explains the four ramping profiles an installer can choose from.
How the Goodman furnace works: Cooling airflow ramping profiles A to D
What this is. Goodman ACVC96, AMVC96, GCVC96 and GMVC96 furnaces have a variable-speed blower that can ease into cooling instead of blasting on at full speed. This page explains the four ramping profiles an installer can choose from.
What happens, in order. Profile A is the simplest: the blower runs at 100 percent airflow, and when cooling stops it keeps going for 1 minute at full speed. Profile B starts at 50 percent for 30 seconds, ramps up to 100 percent, then finishes with the same 1-minute run-on. Profile C starts gently, ramping to 85 percent for about 7 and a half minutes before stepping to 100 percent, then ends with the 1-minute run-on at full. Profile D is the gentlest: 50 percent for half a minute, then 85 percent for about 7 and a half minutes, then 100 percent, and finally a half-minute run-on at 50 percent.
Why it matters. A softer start lets the cooling coil get cold sooner, which helps with comfort and with removing moisture from the air, while a gentle finish keeps the noise down. Your installer chooses the profile.
What is normal. Quiet air at first that gradually builds, then a steady flow. After cooling stops, the fan may carry on for a minute or half a minute.
Safe checks. Replace a dirty filter, make sure the vents are open and not blocked by furniture, and check that the thermostat fan setting is on Auto.
When to call a technician. If the airflow feels weak all the time, or you want a different profile. Aurora Star Tech can adjust it for your home.
Key times at a glance
| What | How long or how much |
|---|---|
| Profile A OFF delay | 1 minute at 100% |
| Profile B 50% step | 30 seconds |
| Profile C 85% run | about 7 1/2 minutes |
| Profile D OFF delay | 1/2 minute at 50% |
Applies to: Multi-speed circulator blower, cooling
Questions about the Goodman furnace
What is the Cooling airflow ramping profiles A to D on a Goodman furnace?
Goodman ACVC96, AMVC96, GCVC96 and GMVC96 furnaces have a variable-speed blower that can ease into cooling instead of blasting on at full speed. This page explains the four ramping profiles an installer can choose from.
Is it normal for my Goodman furnace to do this?
Quiet air at first that gradually builds, then a steady flow. After cooling stops, the fan may carry on for a minute or half a minute.
Who can service my Goodman furnace near me?
Aurora Star Tech Inc. repairs and services Goodman furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.