Goodman-Amana-Daikin heat pump: Communicating defrost and forced defrost
A Goodman ComfortNet heat pump collects frost on its outdoor coil in cold, damp weather and has to melt it off from time to time. This page explains how the communicating system decides to do that.
How the Goodman-Amana-Daikin heat pump works: Communicating defrost and forced defrost
What this is. A Goodman ComfortNet heat pump collects frost on its outdoor coil in cold, damp weather and has to melt it off from time to time. This page explains how the communicating system decides to do that.
What happens, in order. While the heat pump is heating, the outdoor control watches the coil temperature. Once it is below about 31 F, the control counts up the compressor's running time. When that reaches an interval set on the board (30, 60, 90 or 120 minutes) and heat is still being called for, defrost starts. The outdoor fan stops, the reversing valve switches, and the compressor may pause briefly during the shift. The compressor then restarts at high stage while the air handler is asked to run the electric heat and blower at a defrost speed, so the house does not feel a cold draft. Defrost ends when the coil reaches about 75 F or after 10 minutes at most, whichever comes first, and the timer resets. The system then returns to the heating mode it was in. A technician can force a defrost for testing by pressing two buttons on the outdoor board.
What is normal. Steam rising from the outdoor unit, dripping water, a swoosh as the valve shifts, and warm but slightly cooler air for a few minutes.
Safe checks. Keep snow, ice and leaves away from the outdoor unit, with space around it. Make sure the thermostat is in Heat and the filter is clean.
When to call a technician. Thick ice that stays for hours, defrost that never seems to end, or a house that will not warm. Aurora Star Tech can help.
Key times at a glance
| What | How long or how much |
|---|---|
| Defrost interval (dip switch) | 30, 60, 90 or 120 min |
| Start sensing temperature | about 31 F |
| End temperature | about 75 F |
| Max defrost time | 10 min |
Applies to: Goodman ComfortNet ASZC / GSZC / DSZC heat pumps
Questions about the Goodman-Amana-Daikin heat pump
What is the Communicating defrost and forced defrost on a Goodman-Amana-Daikin heat pump?
A Goodman ComfortNet heat pump collects frost on its outdoor coil in cold, damp weather and has to melt it off from time to time. This page explains how the communicating system decides to do that.
Is it normal for my Goodman-Amana-Daikin heat pump to do this?
Steam rising from the outdoor unit, dripping water, a swoosh as the valve shifts, and warm but slightly cooler air for a few minutes.
Who can service my Goodman-Amana-Daikin heat pump near me?
Aurora Star Tech Inc. repairs and services Goodman-Amana-Daikin heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.