Rinnai air handler: Circulating pump exercise
A pump that sits idle all summer can seize up, so your Rinnai hydronic air handler gives its hot water circulating pump a little workout on its own.
How the Rinnai air handler works: Circulating pump exercise
What this is. A pump that sits idle all summer can seize up, so your Rinnai hydronic air handler gives its hot water circulating pump a little workout on its own.
What happens, in order. The control keeps track of how long it has been since the pump last ran. Once 24 hours have gone by without a heating call, it starts the pump itself, as if the thermostat had asked for heat. The pump then runs for one minute and shuts off. After that it rests until the next real call for heat, or until the next 24-hour exercise comes due, whichever arrives first.
What is normal. A faint hum or the sound of water moving through the pipes for about a minute, once a day, even in the middle of summer or when the thermostat is set to off or cool. Nothing heats up in that short time. This feature applies to both the heat pump and the A/C versions of the Canadian hydronic air handler.
Safe checks. Make sure the thermostat is working normally, the filter is clean and the breaker for the air handler is on. Do not open the cabinet or touch the pipes or wiring.
When to call a technician. Call if the pump runs for much longer than a minute, runs constantly, makes grinding or banging noises, or if you see water around the unit. Aurora Star Tech can inspect hydronic air handlers across Vaughan, Toronto and the GTA, and a quick service visit usually settles it.
Key times at a glance
| What | How long or how much |
|---|---|
| Pump run time | 1 min |
| Exercise interval (default) | 24 h |
Applies to: Rinnai Canadian hydronic air handler (heat pump and A/C versions)
Questions about the Rinnai air handler
What is the Circulating pump exercise on a Rinnai air handler?
A pump that sits idle all summer can seize up, so your Rinnai hydronic air handler gives its hot water circulating pump a little workout on its own.
Is it normal for my Rinnai air handler to do this?
A faint hum or the sound of water moving through the pipes for about a minute, once a day, even in the middle of summer or when the thermostat is set to off or cool. Nothing heats up in that short time. This feature applies to both the heat pump and the A/C versions of the Canadian hydronic air handler.
Who can service my Rinnai air handler near me?
Aurora Star Tech Inc. repairs and services Rinnai air handlers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.