KeepRite Performance Series heat pumps with the Fast control board melt frost off the outdoor coil by running a timed defrost, and they offer a gentler option called Quiet Shift. This page explains how both work in everyday terms.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the KeepRite heat pump works: Heat pump (Fast #1174185 board): defrost interval, Quiet Shift and speed-up test

What this is. KeepRite Performance Series heat pumps with the Fast control board melt frost off the outdoor coil by running a timed defrost, and they offer a gentler option called Quiet Shift. This page explains how both work in everyday terms.

What happens, in order. A sensor on the coil closes at about 32 degrees Fahrenheit and starts a timer, which can be set to 30, 60, 90 or 120 minutes. If the coil warms and the sensor opens before the time is up, the timer resets. When it finishes, defrost begins. It ends when the coil warms to about 65 degrees Fahrenheit or after 10 minutes at most. With Quiet Shift turned on, which it is not from the factory, the compressor rests for 30 seconds going into defrost and 30 seconds coming out, which softens the noise when the system reverses. The outdoor fan also stays off an extra 40 seconds on return to heating. Quick test routines on the board belong to technicians.

What is normal. Steam and dripping water from the outdoor unit, a short pause in warm air, a whoosh as the refrigerant changes direction, and, with Quiet Shift, a slightly longer and quieter transition.

Safe checks. Keep snow, ice and leaves away from the outdoor unit and give it a clear couple of feet. Replace a dirty filter, and confirm the thermostat is on Heat.

When to call. Thick ice that does not clear, defrost running constantly, or a house that cools off. Aurora Star Tech can inspect the sensor and control board.

Key times at a glance

WhatHow long or how much
Defrost interval30 / 60 / 90 / 120 min
Defrost startabout 32 F coil
Defrost endabout 65 F coil
Maximum defrost10 min
Quiet Shift30 s compressor off in and out; fan off 40 s extra

Applies to: KeepRite / ICP / Tempstar / Heil Performance Series split heat pumps (defrost control Fast #1174185)

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the KeepRite heat pump

What is the Heat pump (Fast #1174185 board): defrost interval, Quiet Shift and speed-up test on a KeepRite heat pump?

KeepRite Performance Series heat pumps with the Fast control board melt frost off the outdoor coil by running a timed defrost, and they offer a gentler option called Quiet Shift. This page explains how both work in everyday terms.

Is it normal for my KeepRite heat pump to do this?

Steam and dripping water from the outdoor unit, a short pause in warm air, a whoosh as the refrigerant changes direction, and, with Quiet Shift, a slightly longer and quieter transition.

Who can service my KeepRite heat pump near me?

Aurora Star Tech Inc. repairs and services KeepRite heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.