NTI boiler: Light-off sequence and retries
This page describes how your NTI Trinity Tft boiler lights its burner, and what it does when the flame does not catch the first time.
How the NTI boiler works: Light-off sequence and retries
What this is. This page describes how your NTI Trinity Tft boiler lights its burner, and what it does when the flame does not catch the first time.
What happens, in order. Once there is a call for heat and the safety limits are closed, the combustion fan speeds up to a light-off speed. You may briefly see Hold 62 on the display at this point, which is normal. Next, the igniter sparks and the gas valve opens for a trial. A flame rod proves the flame is there. If it is, the burner runs and adjusts its output up and down to match what the house needs. If no flame is proven, the trial ends with a post-purge and the boiler tries again.
If it keeps failing. After three trials without flame, the boiler stops with Hold 110, and the underlying fault is logged as Lockout 109, ignition failed. Hold 62 lasting more than 15 seconds is worth reporting. A flame that is lost after it lit shows as Lockout 106, 107 or 108. A weak flame signal gives Lockout 138, or Alert 449 when the boiler simply holds a higher minimum fan speed for a while.
What is normal. Fan noise ramping up, igniter clicking and a brief hold message.
Safe checks. Check the thermostat, switch and breaker, and clear snow or leaves from the outside pipes. Note the code and reset once only.
When to call a technician. If Hold 110, Hold 62 for more than 15 seconds, or any of the flame lockouts return. If you smell gas, leave and call from outside, then ask Aurora Star Tech for service.
Key times at a glance
| What | How long or how much |
|---|---|
| Ignition trials before stopping | 3 (built-in retry) |
| Cycles seen at commissioning test with flame wire unplugged | 4 ignition cycles, then Hold 110 |
| Hold 62 before light-off | Momentary; investigate at 15 s or more |
| Spark voltage | About 14,000 V |
Applies to: Trinity Tft60, Tft85, Tft110, Tft155, Tft175, Tft200, Tft250, Tft300, Tft399
Error codes linked to this step
NTI code Hold 62NTI code Hold 110NTI code Lockout 109NTI code Lockout 106NTI code Lockout 107NTI code Lockout 108NTI code Lockout 138NTI code Alert 449
Questions about the NTI boiler
What is the Light-off sequence and retries on a NTI boiler?
This page describes how your NTI Trinity Tft boiler lights its burner, and what it does when the flame does not catch the first time.
Is it normal for my NTI boiler to do this?
Fan noise ramping up, igniter clicking and a brief hold message.
Who can service my NTI boiler near me?
Aurora Star Tech Inc. repairs and services NTI boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.