Updated · by Aurora Star Tech Inc.

If the refrigerant pressure in your Carrier Infinity single-stage heat pump goes too high or too low, a pressure switch cuts the compressor to protect it. This page explains the automatic pause, retry and lockout.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the Carrier heat pump works: Single-stage communicating heat pump: pressure switch protection and lockout

What this is. If the refrigerant pressure in your Carrier Infinity single-stage heat pump goes too high or too low, a pressure switch cuts the compressor to protect it. This page explains the automatic pause, retry and lockout.

What happens, in order. When either the high or low pressure switch opens, the compressor stops and a matching fault code shows. The outdoor fan keeps running for 15 minutes to help conditions recover. After 15 minutes, if cooling is still wanted and the switch has reset, the compressor starts again. If the switch is still open, the fan shuts off too and the unit resumes when the switch closes. If a switch trips on five cycles in a row, the unit locks out for 4 hours and shows a lockout code. In low-ambient cooling with the Infinity control, the low pressure switch is ignored for the first 3 minutes, and a later trip turns off the fan for 10 minutes.

What is normal. A single pause and automatic restart on a very hot or cold day, with a code that clears itself.

Safe checks. Replace a dirty filter, clear the outdoor coil of leaves and cottonwood, and make sure vents are open. You can switch the system off at the thermostat for a few minutes and back on once.

When to call. Repeated trips, a lockout code or warm air all mean a technician is needed, and Aurora Star Tech can help.

Key times at a glance

WhatHow long or how much
Fan run after switch trip15 min
Retry after trip15 min
Consecutive trips to lockout5
Lockout time4 hours
Low ambient LPS ignore at start3 min
Low ambient fan off after LPS trip10 min

Applies to: Carrier / Bryant / Payne split heat pumps with HK32EA defrost control boards (Performance Series and Comfort Series)

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the Carrier heat pump

What is the Single-stage communicating heat pump: pressure switch protection and lockout on a Carrier heat pump?

If the refrigerant pressure in your Carrier Infinity single-stage heat pump goes too high or too low, a pressure switch cuts the compressor to protect it. This page explains the automatic pause, retry and lockout.

Is it normal for my Carrier heat pump to do this?

A single pause and automatic restart on a very hot or cold day, with a code that clears itself.

Who can service my Carrier heat pump near me?

Aurora Star Tech Inc. repairs and services Carrier heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977