Updated · by Aurora Star Tech Inc.

A Carrier Infinity variable-speed heat pump (25VNA8 or 24VNA9) is deliberately slow to start after power returns. This page explains the waits and why they protect the compressor.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the Carrier heat pump works: Variable-speed unit: power-up and compressor time delays

What this is. A Carrier Infinity variable-speed heat pump (25VNA8 or 24VNA9) is deliberately slow to start after power returns. This page explains the waits and why they protect the compressor.

What happens, in order. Whenever high-voltage power is first applied, the control holds the compressor for 10 minutes to warm the oil in the compressor base. After any run, power-up or brown-out, the compressor then waits 3.5 minutes before starting. At the end of each run, a pressure equalizer valve opens for 150 seconds to balance pressures, then closes for 15 seconds before the next start. The crankcase heater is managed by the control and works whenever the outdoor unit has power, and the compressor is also gently pulsed now and then during long off periods to keep it warm. If the incoming electrical supply sags too low for a few seconds, the unit stops, and it will not run again until the supply has properly recovered. It returns to standby 2 minutes after the last valid communication.

What is normal. Ten minutes of nothing after the power has been off, then a short wait on later starts, and a hissing sound as pressures balance when the unit stops.

Safe checks. Leave the outdoor power on, especially in winter. Check the thermostat, filter and breakers, and clear the outdoor unit of leaves and snow.

When to call. Code 46 or repeated power-related stops can point to a supply issue, so call Aurora Star Tech.

Key times at a glance

WhatHow long or how much
Sump warm-up at power-up10 min
Compressor delay3.5 min
PEV open after run150 s
PEV closed before next start15 s
Aux heat off delay after defrost15 s
Brown-out cutoutbelow 187 V for 4 s
Brown-out recover190 V

Applies to: Carrier Infinity 25VNA8 variable-speed heat pump and 24VNA9 variable-speed air conditioner

Error codes linked to this step

Carrier code 46

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the Carrier heat pump

What is the Variable-speed unit: power-up and compressor time delays on a Carrier heat pump?

A Carrier Infinity variable-speed heat pump (25VNA8 or 24VNA9) is deliberately slow to start after power returns. This page explains the waits and why they protect the compressor.

Is it normal for my Carrier heat pump to do this?

Ten minutes of nothing after the power has been off, then a short wait on later starts, and a hissing sound as pressures balance when the unit stops.

Who can service my Carrier heat pump near me?

Aurora Star Tech Inc. repairs and services Carrier heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.