Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

HTP boiler: Indirect water heater call

Updated · by Aurora Star Tech Inc.

Many homes with an HTP Elite EL boiler also heat water in a separate insulated tank, called an indirect water heater. This page explains how the boiler decides to reheat that tank and how it keeps your radiators from being forgotten.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the HTP boiler works: Indirect water heater call

What this is. Many homes with an HTP Elite EL boiler also heat water in a separate insulated tank, called an indirect water heater. This page explains how the boiler decides to reheat that tank and how it keeps your radiators from being forgotten.

What happens, in order. A temperature sensor on the tank, or in some homes a simple aquastat, notices when the tank has cooled below the hot water target by more than a small offset. The target is 119 °F from the factory with a 7 °F differential. The tank pump then starts and the boiler runs at its hot water supply temperature, which is 180 °F by default. As with heating, if the boiler water is already too hot the display shows TEMPER BLOCKING and waits. The call continues until the tank is above its target. The tank pump can run on afterwards for a set time, zero minutes by default.

Priority. Hot water is normally served first, but a priority timer, 30 minutes by default, limits how long the boiler can focus on the tank and guarantees a minimum time for central heating.

What is normal. The boiler firing right after a long shower, radiators cooling briefly while the tank is reheated, the display showing DHW, and the pump continuing for a short while.

Safe checks. Check the water is not set too high or low on the tank, the boiler has power and the pressure gauge is in range. Be careful with very hot water at taps.

When to call a technician. If water stays lukewarm, the display shows an error code, or you see leaks, book Aurora Star Tech.

Key times at a glance

WhatHow long or how much
DHW set point119 F default
DHW differential7 F default
Boiler supply for DHW180 F default
DHW post pump0 min default (0 to 10)
DHW priority30 min default (0 to 60)

Applies to: EL-80, EL-110, EL-150, EL-220, EL-299, EL-399 (N/LP)

Error codes linked to this step

HTP code DHW

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the HTP boiler

What is the Indirect water heater call on a HTP boiler?

Many homes with an HTP Elite EL boiler also heat water in a separate insulated tank, called an indirect water heater. This page explains how the boiler decides to reheat that tank and how it keeps your radiators from being forgotten.

Is it normal for my HTP boiler to do this?

The boiler firing right after a long shower, radiators cooling briefly while the tank is reheated, the display showing DHW, and the pump continuing for a short while.

Who can service my HTP boiler near me?

Aurora Star Tech Inc. repairs and services HTP boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977