Rinnai Boiler Error Codes

Updated · by Aurora Star Tech Inc.

108 Rinnai Boiler error codes and diagnostic codes, with causes and troubleshooting steps for each. Select a code, or find your model below.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Rinnai Boiler error codes list

CodeMeaningSeverity
00-AParameter menu entryLow
021Too Long DHW Continuous OperationMedium
60Descaling countdown (minutes remaining)Low
100Air intake/exhaust blockage or full condensate trapCritical
110Ignition failureHigh
120Flame failure (flame lost during operation)High
140Overheat switch tripped (heat exchanger overheating)Critical
150Venturi control faultHigh
161High outgoing temperatureHigh
170Venturi blockage / position mismatchHigh
180Gas valve air/fuel adjustment limit reachedHigh
190Electrical grounding / short in DC circuitHigh
210Data transfer errorMedium
220Gas valve position not detected (reed switch)Medium
250Condensate pump switch tripped (accessory)High
303Secondary system thermistor faultMedium
310Freeze protection thermistor faultMedium
321Outgoing Thermistor (Combi Only)Medium
331Heat Exchanger Thermistor (Combi Only)Medium
341Inlet Thermistor (Combi Only)Medium
353CH supply thermistor faultMedium
363CH return thermistor faultMedium
371Indirect tank thermistor faultMedium
380Exhaust thermistor faultMedium
393Outdoor temperature sensor faultMedium
400Water pressure sensor communication faultMedium
430High or low system water pressureHigh
443Low water cut-off (LWCO) activatedHigh
520Gas solenoid valve circuit – flame after valve closeCritical
540High exhaust (flue gas) temperatureCritical
610Combustion fan motor speed faultHigh
631DHW Recirculation Pump (Combi Only)Low
651Water Flow Control (Combi Only)Medium
661By-Pass (Combi Only)Medium
6703-Way Valves (Combi Only)Medium
681Hot Water Supply Temperature Abnormality (Combi Only)Medium
700PC Board faultHigh
710Gas solenoid circuit – valve position mismatchHigh
720Flame rod faultHigh
7630-10V external control input over-voltageMedium
831Indirect tank call running too longMedium
890Freeze condition detectedHigh
999PC Board / software mismatchHigh
A XXDe-aeration runningLow
Block 01External safety contact openMedium
Block 05Outdoor sensor not connectedLow
Block 60Wrong minimum/maximum power parameterMedium
Block 67Supply/return sensor difference with burner offMedium
Block 85No water flow detectedMedium
COdEAccess code entryLow
CopyFactory settings restoredLow
dESDescaling (automated flush) modeLow
E00Poor flame formation (flame sensed with burner off)High
E02No flame formation (ignition failure)High
E04Voltage interruption / error read-out interruptedMedium
E05Adjustment error (listed in short reference)Medium
E12High limit stat openHigh
E14Supply sensor T1 faultHigh
E18Maximum supply temperature exceededHigh
E19Maximum return temperature exceededHigh
E28Fan speed not reported backHigh
E31Supply sensor T1 shortedHigh
E32Return sensor T2 shortedHigh
E36Supply sensor T1 openHigh
E37Return sensor T2 openHigh
E69No or incorrect displayMedium
E393Outdoor sensor harness disconnectedMedium
E430Low water pressure in the heating systemHigh
ECLReset complete (gas solenoid circuit)Low
EndDescaling completeLow
ERROError chapterLow
FFFMaintenance performed markerLow
FHForced High Fire ModeLow
FILLWater pressure low / system emptyLow
FLForced Low Fire ModeLow
FUSE24 V fuse defectiveHigh
GoodGood state (normal)Low
Green button resetRestore factory parametersLow
HIGHWater pressure too highLow
Ignition safety testTest ionization lockoutLow
INFOInformation chapterLow
LCLime scale detected on DHW sideMedium
PVenturi reset: first screenLow
PARAParameter chapterLow
Parameter modeParameter settings menuLow
PCLVenturi reset acceptedLow
Perf dataPerformance data menuLow
P XXWater pressure read-outLow
rnSRinsing stage (descaling flush)Low
SESecondary unit error (cascade)Medium
SERVService chapterLow
SERVICEService dueLow
SSService Soon reminderLow
Status 0No heat demandLow
Status 1Fan pre/post purgeLow
Status 2Ignition phaseLow
Status 3Burner on, central heatingLow
Status 4Burner on, domestic hot waterLow
Status 5Fan checkLow
Status 6Burner off, demand pendingLow
Status 7Pump overrun, central heatingLow
Status 8Pump overrun, hot waterLow
Status 9Burner off, supply temperature too highLow
Status AAutomatic de-aeration programLow
StBYStandby / exit to read-outLow
STOPFill target reachedLow
SW1-SW3PC board buttons (SW1, SW2, SW3)Low
Technical read-outTechnical read-outLow

Find codes by Rinnai model

I-Series Plus 150K and smaller

IP060SIP090SIP120SIP150S

I-Series Plus 175K and higher

IP175SIP199S

Boiler troubleshooting guides

Homeowner help: Boiler Not Heating: What to Check

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977