Rinnai Boiler: Nothing Happens When DHW Water Flow Is Activated (Combi Only)
Nothing Happens When DHW Water Flow Is Activated (Combi Only) on a Rinnai boiler: No burner firing when hot water is drawn, with no code shown.
Applies to: I-Series Plus combi boiler
Common causes of nothing happens when dhw water flow is activated (combi only)
- Flow below minimum needed to fire
- Flow control sensor faulty
- Clogged inlet water filter
- Hot and cold lines reversed on new installs
- Inlet water too hot
- Integrated boiler pump not operating
- DHW operation switch off
How to fix nothing happens when dhw water flow is activated (combi only): step by step
- Verify the minimum flow rate to fire the boiler is reached.
- Measure the resistance of the flow control sensor (see Electrical Diagnostics).
- Clean the inlet water supply filter.
- On new installs, confirm hot and cold lines are not reversed.
- Confirm the inlet water temperature is not too high.
- Confirm the integrated boiler pump operates properly.
- Confirm the DHW operation switch is on.
If the unit shows an error code, look it up: Rinnai Boiler codes
Source: Rinnai I-Series Plus IP060160C installation and operation manual, p. 116. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.