Rinnai Error Code 100: Air intake/exhaust blockage or full condensate trap (Boiler)

Updated · by Aurora Star Tech Inc.

Rinnai error code 100 on a boiler means: Air intake/exhaust blockage or full condensate trap. It is also called Rinnai diagnostic code 100.

Critical severityBoilerAlso Combi BoilerI-Series Plus 150K and smaller · I-Series Plus 175K and higher

Homeowner? What Rinnai code 100 means for you

Stop and call Your boiler is reporting: Air intake/exhaust blockage or full condensate trap. This code is a safety shutdown. Turn the boiler off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Rinnai error code 100 mean?

The control has detected a restriction in the intake or exhaust path. A backed-up condensate trap inside the boiler can also restrict airflow and trigger it.

Applies to: I-Series Plus boilers — 150K BTU and smaller and 175K BTU and higher (Combi and Solo)

Common causes of Rinnai code 100

  • Clogged or frozen condensate drain backing up the trap
  • Dirty inlet air filter
  • Blocked intake/exhaust terminations or debris in vent piping

A technician checks these and 5 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Rinnai models that use code 100

IP060SIP090SIP120SIP150SIP175SIP199S

Other Rinnai Boiler codes

CodeMeaning
110Ignition failure
120Flame failure (flame lost during operation)
140Overheat switch tripped (heat exchanger overheating)
150Venturi control fault
170Venturi blockage / position mismatch
180Gas valve air/fuel adjustment limit reached
190Electrical grounding / short in DC circuit
210Data transfer error
220Gas valve position not detected (reed switch)
250Condensate pump switch tripped (accessory)
303Secondary system thermistor fault
310Freeze protection thermistor fault

All Rinnai Boiler error codes →

Rinnai code 100: homeowner questions

What does Rinnai code 100 mean?

Air intake/exhaust blockage or full condensate trap. The control has detected a restriction in the intake or exhaust path. A backed-up condensate trap inside the boiler can also restrict airflow and trigger it.

Is it safe to keep using my boiler with code 100?

No. Code 100 is a safety shutdown, so keep the boiler off until a licensed technician has checked it.

Can I reset Rinnai code 100 myself?

Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.

Who can fix Rinnai code 100 near me?

Aurora Star Tech Inc. repairs Rinnai boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Rinnai Troubleshooting I-Series Plus Boiler Diagnostic Codes (800000375), p.4–5. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.