Rinnai Error Code E02: No flame formation (ignition failure) (Boiler)

Updated · by Aurora Star Tech Inc.

Rinnai error code E02 on a boiler means: No flame formation (ignition failure). It is also called Rinnai diagnostic code E02.

High severityBoilerE-Combi (E50CRN · E75CRN/E75CRP · E110CRN/E110CRP)

Homeowner? What Rinnai code E02 means for you

Call a technician Your boiler is reporting: No flame formation (ignition failure). The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Rinnai error code E02 mean?

Lockout: the burner did not light. The boiler makes one start and several restarts with rising start load, then locks out.

Applies to: E50CRN; E75CRN; E75CRP; E110CRN; E110CRP

Common causes of Rinnai code E02

  • Gas valve closed or no gas supply
  • No power to gas valve or valve not opening
  • Gas inlet pressure too low (below 7 in. W.C. / 17 mbar at start)

A technician checks these and 3 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Rinnai Boiler codes

CodeMeaning
Block 60Wrong minimum/maximum power parameter
Block 67Supply/return sensor difference with burner off
Block 85No water flow detected
COdEAccess code entry
CopyFactory settings restored
E00Poor flame formation (flame sensed with burner off)
E04Voltage interruption / error read-out interrupted
E05Adjustment error (listed in short reference)
E12High limit stat open
E14Supply sensor T1 fault
E18Maximum supply temperature exceeded
E19Maximum return temperature exceeded

All Rinnai Boiler error codes →

Rinnai code E02: homeowner questions

What does Rinnai code E02 mean?

No flame formation (ignition failure). Lockout: the burner did not light. The boiler makes one start and several restarts with rising start load, then locks out.

Is it safe to keep using my boiler with code E02?

It depends on the cause. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Rinnai code E02 myself?

You can try one reset (power off for 30 seconds, then on). If Rinnai code E02 comes back, the cause is still there and a licensed technician should check it.

Who can fix Rinnai code E02 near me?

Aurora Star Tech Inc. repairs Rinnai boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Rinnai E-Combi Series Installation & Servicing Instructions (8U516009 V0116), p.71-76 (15.1, 15.3). Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.