Rinnai Boiler: Room air corrosive environment restrictions
Room air corrosive environment restrictions on a Rinnai boiler: Limits on using room air where combustion air contains acid-forming or corrosive chemicals.
Applies to: Room air combustion air
Common causes of room air corrosive environment restrictions
- Acid-forming chemicals such as sulfur, fluorine and chlorine cause rapid damage and can become toxic in combustion air.
- Appliance failure from corrosive air is not covered by warranty.
How to fix room air corrosive environment restrictions: step by step
- Install as direct vent where indoor air is corrosive.
- Do not use room air where bleach, ammonia, cat litter, aerosol sprays, cleaning solvents, varnish, paint or air fresheners are present or stored nearby.
- Do not take combustion air from areas that can create negative pressure, such as exhaust fans or powered ventilation fans.
If the unit shows an error code, look it up: Rinnai Boiler codes
Source: Rinnai I-Series Plus IP060160C installation and operation manual, p. 41. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.