Rinnai Boiler: Hot water works, no central heating

Updated · by Aurora Star Tech Inc.

Hot water works, no central heating on a Rinnai boiler: DHW is available but there is no space heating.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: E50CRN; E75CRN; E75CRP; E110CRN; E110CRP

Common causes of hot water works, no central heating

  • CH program key off
  • On/off room thermostat sending no call
  • RS100 with outdoor sensor: outdoor temperature above the Eco setting (default 70 F)
  • Three-way valve not going to CH position

How to fix hot water works, no central heating: step by step

  1. Switch central heating on.
  2. Check the room thermostat.
  3. With RS100, check INFO step 7 and the timer and room temperature settings.
  4. Check three-way valve wiring; replace the valve motor if needed.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Rinnai Boiler codes

Models

I-Series Plus 150K and smaller

IP060SIP090SIP120SIP150S

I-Series Plus 175K and higher

IP175SIP199S

Source: Rinnai E-Combi Series Installation & Servicing Instructions (8U516009 V0116), p.77 (15.4). Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.