Rinnai Boiler: Fill the condensate collector before operation and before venting

Updated · by Aurora Star Tech Inc.

Fill the condensate collector before operation and before venting on a Rinnai boiler: The condensate collector must be filled with water before the boiler runs and before the vent system is installed, otherwise exhaust gas can enter the building. Failure to fill it can cause severe injury or death.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: I-Series Plus before first start and venting

How to fix fill the condensate collector before operation and before venting: step by step

  1. Pour approximately 10 oz (1.25 cups) of water directly into the boiler exhaust port.
  2. Do this with the 2 in. PVC adapter still fitted to the exhaust port.
  3. Complete this before installing the vent system.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Rinnai Boiler codes

More commissioning tips for boiler

Source: Rinnai I-Series Plus IP060160C installation and operation manual, p. 25. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.